background image

GUARANTEE

Your Ultrasonic Cleaner has been carefully manufactured and 100% tested using high quality assured components. 

It is guaranteed against faulty workmanship and materials for a period of 12 months from the date of purchase. In 

the unlikely event that a failure should occur, the unit will be repaired or replaced* free of charge when returned, 

postage paid, to the address below within the guarantee period. This guarantee DOES NOT include damage or 

failure resulting from misuse, damage in transit or failure by the user to comply with the Dos and Don’ts (this list is 

not exhaustive).  Your statutory rights under common law are in no way affected by this guarantee.

James Products Ltd, 

Church Close Business Park, Todber, Sturminster Newton, Dorset DT10 1JH, England

Tel: +44 (0)1258 820100   Fax: +44 (0)1258 820550   Email: sales@jamesproducts.co.uk

When returning your unit please call our Returns Department on +44 (0)1258 820100 for a RMA (Returns 

Materials Authorisation) number. Please return your unit in its original packaging along with a covering 

letter stating when and where you purchased the unit and a description of the problem encountered.  

If the unit is within the guarantee period please enclose proof of purchase.

LIMITED WARRANTY  

Consequential and incidental damages, including without limitation, loss of property and 

those arising from breach of any express or implied warranty, are not the responsibility of James Products Limited 

and to the extent permitted by law, are excluded.

In accordance with its policy of progressive product design, James Products Ltd reserves the right to change 
product specifications without prior notice.

*Repair or replacement is at the discretion of the manufacturer.

Registered in England No. 5250754
Registered Office: 

James Products Ltd, Church Close Business Park, Todber, Sturminster Newton, Dorset DT10 1JH, England

www.jamesproducts.co.uk

SPECIFICATIONS

Description

 

Professional Ultrasonic Cleaner

Model

 

9050 TOUCH

Tank Capacity

 

     7.5 L / 

Max. 6.0 L / 1.6 gallon (US)

 

2.0 gallon (US) 

Min. 4.3 L / 1.1 gallon (US)

Tank Size

 

33.1 x 23.8 x 10.5 cm / 13.0” x 9.4” x 4.1”

Longest Item Fits inside Tank

 

37.0 cm / 14.4”

Power Supply

 

410 W (AC 220~240V 50/60Hz)

Digital Timer Settings

 

     10min   15min   20min   25min   30min   5min 

Drainage

 

Drainage valve

Ultrasonic Frequency

 

35,000 Hz

Tank Material

 

Stainless Steel SUS304

Housing Material

 ABS

Net Weight

 

9.8 kg / 21.8 lb

Gross Weight

 

11.1 kg / 24.7 lb

Unit Size

 

54.1 x 33.7 x 27.7 cm / 21.3” x 13.3” x 10.9”

Summary of Contents for 9050 Touch

Page 1: ...tings Independent control circuit 40 higher efficiency not susceptible to for each ultrasonic transducer interference more durable Multiple circuit protectors When overloaded or improperly used the protectors shut down the power to certain areas to protect the machine Moisture proofed PCB with Capable for different working environments with better industrial IC anti interference performance 3 x co...

Page 2: ...lves tools fuel injectors etc BABY ITEMS Toys baby items speech therapy tools etc SILVER COPPER OR BRASS Silverware silver copper or brass decorations etc LAB ITEMS Test tubes beakers flasks etc PCB INKJET CARTRIDGES PCBs from mobile phones and MP4 ink cartridges etc BRASS GUN PARTS Reusable brass gun parts etc GOLF CLUBS Golf clubs and golf balls CRYSTALS Crystals ELECTRICAL PARTS Terminals for r...

Page 3: ...ttings 3 temperature settings simple to operate Control panel with capacitive sensing technology durable reliable resistant to water and harsh chemicals Electrical circuit features 1 Three transducers each has an independent PCB control The output power is increased by 40 2 Multiple circuit protectors a Thermal switch to prevent running dry If temperature is too high the switch cuts off power for ...

Page 4: ...e the warnings in all sections If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard SAFETY PRECAUTIONS Keep it away from children This appliance can be used by children aged from 8 years and above if they have been given supervision or instruction concerning use of the appliance in a safe way and if th...

Page 5: ...nplug grasp the plug not the cord Unplug from outlet when not in use and before servicing or cleaning To reduce the risk of electrical shock do not put the appliance in water or other liquid Do not place or store appliance where it can fall or be pulled into a tub or sink All servicing of this product including transducer replacement is to be conducted by qualified service personnel Do not operate...

Page 6: ...l panel F Drainage pipe fitting G Drainage valve handle H Cover holder I Power switch J Power socket A B C D E F G H I J Hose Power Cord INCLUDED ACCESSORIES OPTIONAL ACCESSORIES Indirect cleaning tank Double Beaker and beaker holder Stainless steel rack and tray Suspendible Basket ...

Page 7: ...rned on Press Heater button again dims indicating the heater is turned off 7 Normal Cleaning Status Illuminated normal cleaning is underway 8 Heater Button Pressing heater button flashes indicating that the heater is turned on To cancel heating press heater button twice again dims indicating the heater is turned off 9 Temperature Set Button 3 set temperatures C F can be selected Press Temp button ...

Page 8: ...od or organic tissues left after use They need to be removed with ultrasonic cleaners before disinfection 4 Dental Clinics Dental clinics can use ultrasonic cleaners to clean dental instruments and to remove blood and small particles left on the instruments before disinfection 5 Electrical Component Manufacturers Terminals on AC contactors and relays need to be kept clean to prevent sparking and n...

Page 9: ...ltrasonic cleaners and pure alcohol to recover the functions Use the Indirect Cleaning method for small sized PCBs 10 Printing Shops Unblocking dried printer heads or ink cartridges Large printers and inkjet printers often have dried printer heads or ink cartridge ports Replacing them with new ones is very costly Adding acetone or SeaClean2 and using an ultrasonic cleaner with a couple of minutes ...

Page 10: ...on Press Time button to set the timer to 10 minutes Press On Off button to start cleaning Ultrasonic waves will penetrate the container and clean the items 10 INDIRECT CLEANING Avoid any acetone acid alcohol amonia or solvents from contacting the plastic housing and control panel to prevent corrosion Use Indirect Cleaning and a glass or metal container for using such solutions COMMON CLEANING METH...

Page 11: ...ed special cleaning Suitable Locations gold silver copper or brass product manufacturers shooting clubs Cleaning Method 1 Put the items in the basket and then in the tank add water to a level between MIN and MAX and above the area to be cleaned 2 Add special solution SeaClean2 that can remove silver or copper oxidation according to the ratio recommended typically 1 10 Use special solutions accordi...

Page 12: ...n Prolonged cleaning time may result in a Loosening of the screws if used b If items are plated and have existing cracks the cracks may become more pronounced c Coatings with pre existing damages may experience more peeling Press On Off button to start cleaning The digital timer will count down to show the remaining cleaning time When it displays the cleaning is done To stop cleaning at any time p...

Page 13: ...on When the water reaches the set temperature dims indicating the heater is turned off To ensure safety the unit is designed with dual protection The heater will be turned off automatically if it has been running for 50 minutes 4 Thermometer lights up to indicate the percentage of the set temperature reached 30 60 90 100 0 30 60 90 Made from a unique formula containing natural products mixing care...

Page 14: ...is repaired Do not run the unit for extended time or continuously The unit is designed with overheat protection If the unit has been running for 45 minutes it is recommended to stop the unit for about 20 minutes to prolong the life of the unit Do not keep water in the cleaning tank for a long time After cleaning is completed open the drainage valve to drain the dirty water Clean and wipe the tank ...

Page 15: ...chnology and quality It can be used to isolate the cleaning and the solution from the main cleaning action It also reduces the amount of special solution needed BEAKER AND BEAKER HOLDER INDIRECT CLEANING Put the beaker holder and beaker s across the main cleaning tank as shown Add water to the main tank so the water level reaches the beaker s Add required solution into the beaker s It can be used ...

Page 16: ...problem encountered If the unit is within the guarantee period please enclose proof of purchase LIMITED WARRANTY Consequential and incidental damages including without limitation loss of property and those arising from breach of any express or implied warranty are not the responsibility of James Products Limited and to the extent permitted by law are excluded In accordance with its policy of progr...

Reviews: