background image

4. Turn the power switch on. Press Temp button to set the water temperature to 45ºC (113ºF). Press Heater 

button to turn on the heater,   flashes. Close the lid. LED 

 lights up. When water reaches the set 

temperature,   dims, indicating the heater is turned off. 

5. Press Time button to set the timer to 15 minutes. Press On/Off button to start cleaning. Grease will dissipate 

and appear to be like black smoke in the water.

6. When it stops, open the drainage valve to release the dirty water. Close the valve afterwards.

7. Clean the tank and add fresh water. Wash the items for another 3 minutes to remove the residual debris 

and the detergent.

Silver, copper or brass items with oxidation which has 

darkened the items will need special cleaning.

Suitable Locations: 

silver, copper or brass product 

manufacturers, home, shooting clubs.

Cleaning Method: 

Put the items in the basket and then in 

the tank, add water to a level between “MIN” and ”MAX” and 

above the area to be cleaned.
2. Add special solution (SeaClean2) that can remove silver 

or copper oxidation according to the ratio recommended 

(typically 1:10), Use special solutions according to the 

instructions for brass cartridges.
3. Turn the power switch on. Press Temp button to set the 

water temperature to 50ºC (122ºF). Press Heater button to turn 

on the heater,   flashes. Close the lid. LED 

 lights up 

indicating the percentage range of the set temperature being 

reached. When water reaches the set temperature,    dims, 

indicating the heater is turned off.

4. Press 

 

h/min button to set solution usage time. Each pressing increases the time by 20 minutes. Press 

 

button to reduce the time by 20 minutes each time. Common time is 

 or 

. Refer to the instruction from 

the solution manufacturer.
5. Press Time button to set the timer to 15 minutes.
6. Press Function button to select the degas function. 

 

button illuminates. Press On/Off to start degassing. 

After 90 seconds it changes over to normal cleaning automatically.
7. When it is done, remove the basket and the items. Rinse the items with tap water or follow steps 6 and 7 in 

the 

Enhanced Cleaning

 section.

Warm water and dishwashing liquid can soften grease and improve cleaning efficiency.

 SPECAL CLEANING

The heater has dual protection. It will be turned off automatically after 50 minutes.

During cleaning, debris will come off the items like “smoke”. Water will become murky. This method will 

remove silver or copper oxidation and debris in the decorating patterns and crevices and make the 

items like new again.

13

Summary of Contents for ULTRA 9020

Page 1: ...rature thermometer degas and solution usage timer Independent control circuit 40 higher efficiency not susceptible to for each ultrasonic transducer interference more durable Multiple circuit protecto...

Page 2: ...4 Suspendible basket to drain water conveniently 2 x industrial grade ultrasonic transducers 2 x 55 W 110 W 2 x ceramic heaters 2 x 80 W 160 W 3 x colour LED display 1 to 30 minute full range timer 5...

Page 3: ...perate the device unattended Follow the manual to operate the device Do not use components unapproved by the manufacturer When removing the power cord from the socket grab the power plug not the cord...

Page 4: ...fore servicing or cleaning To reduce the risk of electrical shock do not put the appliance in water or other liquid Do not place or store appliance where it can fall or be pulled into a tub or sink Al...

Page 5: ...easily remove the debris 3 Biology Chemical Laboratories Labs can use ultrasonic cleaners to clean test tubes and other glass or metal containers to remove residual chemicals and debris that can affec...

Page 6: ...raditional methods 9 Special Education Institutes Kindergartens Speech therapy tools or small toys that are reused need to be cleaned to prevent the growth and spread of bacteria Ultrasonic cleaning c...

Page 7: ...ands shavers or razors Ultrasonic cleaning can clean the debris in the crevices It is quick and convenient This model has a large tank When cleaning small items the Indirect Cleaning method can be use...

Page 8: ...gears valves tools fuel injectors etc BABY ITEMS Toys baby items speech therapy tools etc SILVER COPPER OR BRASS Silverware silver copper or brass decorations etc LAB ITEMS Test tubes beakers flasks...

Page 9: ...e pipe fitting E Drainage valve handle F Control panel G Handles H Power switch I Power socket J Cover holder Indirect cleaning tank Size 21 7x18 5x7 4 cm Capacity 2 1 L Internal size 19 8x16 6x7 35 c...

Page 10: ...8 PRODUCT EXPLODED VIEW...

Page 11: ...l valve Standard part 23 Bracket ABS 24 Valve handle ABS 25 Elbow ABS 26 Inner tank ABS 27 Bottom cover ABS 28 Power PCB 1 94Vo 29 Power PCB 2 94Vo 30 Right cover ABS 31 Right down handle ABS 32 Right...

Page 12: ...ater button again dims indicating the heater is turned off 10 Working Status Green Ready G Normal working status ready to use Red Overheat R Under overheat protection 20 minutes or more of waiting tim...

Page 13: ...ton to select the temperature in the following sequence 40 C or 104 F 45 C or 113 F 50 C or 122 F 55 C or 131 F 60 C or 140 F 17 Timer Quick Set Button Press Time button LED display shows Each pressin...

Page 14: ...ower switch on Press Time button to set the timer to 10 minutes Press On Off button to start cleaning Ultrasonic waves will penetrate the container and clean the items NOTE Optional stainless steel in...

Page 15: ...r brass cartridges 3 Turn the power switch on Press Temp button to set the water temperature to 50 C 122 F Press Heater button to turn on the heater flashes Close the lid LED lights up indicating the...

Page 16: ...utes Common cleaning times are 5 10 or 15 minutes Prolonged cleaning time may result in a Loosening of the screws if used b Increasing pre existing cracks c Peeling of coating which was already separa...

Page 17: ...o speed up the mixing and to use less solution use degas function Press TIME button to set the timer to 10 minutes then press Function button illuminates Press On Off to start degassing It changes ove...

Page 18: ...r approximately 15 minutes respectively to ensure safety The unit will be disabled until it is repaired Do not run the unit for extended time or continuously The unit is designed with overheat protect...

Page 19: ...direct cleaning SPECIFICATIONS Description Professional Ultrasonic Cleaner Model ULTRA 9020 Tank Capacity 6 0 L Max 5 0 L 1 3 gallon US 1 6 gallon US Min 3 35 L 0 9 gallon US Tank Size 32 3 x 20 5 x...

Page 20: ...g your unit please call our Returns Department on 44 0 1258 822516 for a RMA Returns Materials Authorisation number Please return your unit in its original packaging along with a covering letter stati...