Page 66
1998-2006 Edition
SYMPTOM #10
PROBABLE CAUSE
SOLUTION
When the Fuel Control Knob is set on
"1", the stove seems to burn normally
for a while but, eventually, the fire
goes out.
1. Draft Control Knob is set
too high.
2. Fuel Feed Setting on
control board is set too
low.
1. Reduce the Draft Control Knob Setting
when burning on the "1" setting of the Fuel
Control Knob.
2. At lower altitudes, the higher oxygen
density in the air may cause the pellets to
burn too quickly. Although the efficiency
of the stove is significantly higher, the
pellets may burn too fast to maintain the
fire. Adjust the LOW fuel feed rate on the
control board higher according to this
manual. Specifically, consult Page 56
"Control Board Program Parameters
Tables" and Page 57 "Program Selection
Information". Contact your Dealer for more
detailed instructions.
SYMPTOM #11
PROBABLE CAUSE
SOLUTION
The Fuel Control Knob is set on "1" (or
1. Draft Control Knob is set
1. Reduce the Draft Control Knob Setting
the wall thermostat is in the OFF
too high.
when burning on the "1" setting of the Fuel
position if running in Semiautomatic
Control Knob.
mode) and burned overnight. In the
morning, the firepot is full of unburned
pellets and fire is out.
2. Fuel Feed Setting on
control board is set too
low.
2. At lower altitudes, the higher oxygen
density in the air may cause the pellets to
burn too quickly. Although the efficiency
of the stove is significantly higher, the
pellets may burn too fast to maintain the
fire. Adjust the LOW fuel feed rate on the
control board higher according to this
manual. Specifically, consult Page 56
"Control Board Program Parameters
Tables" and Page 57 "Program Selection
Information". Contact your Dealer for more
detailed instructions.
3. Pellets are tunneling
3. Clean hopper inner surface and apply
inside the hopper
Teflon lubricant spray to entire surface.
(pellets are not sliding
down the hopper sides).
Summary of Contents for J1000B
Page 2: ......
Page 8: ...Page vi 1998 2006 Edition ...
Page 16: ...Page 8 1998 2006 Edition ...
Page 20: ...Page 12 1998 2006 Edition ...
Page 36: ...Page 28 1998 2006 Edition ...
Page 44: ...Page 36 1998 2006 Edition ...
Page 45: ...Page 37 1998 2006 Edition ...
Page 46: ...VIII 5 Jamestown Control Panel Page 38 1998 2006 Edition ...
Page 61: ...Page 53 1998 2006 Edition ...
Page 62: ...Page 54 1998 2006 Edition ...
Page 63: ...Page 55 1998 2006 Edition ...
Page 64: ...Page 56 1998 2006 Edition ...
Page 69: ...Page 61 1998 2006 Edition ...
Page 70: ...Page 62 1998 2006 Edition ...
Page 79: ...Appendix A 3 1998 2006 Edition ...
Page 80: ...Appendix A 4 1998 2006 Edition ...
Page 81: ...Appendix A 5 1998 2006 Edition ...
Page 82: ...Appendix A 6 1998 2006 Edition ...
Page 84: ...Appendix B 2 1998 2006 Edition ...
Page 87: ...APPENDIX E AUGER MOTOR BRACKET INSTALLATION Appendix E 1 1998 2006 Edition ...
Page 90: ...Appendix F 3 1998 2006 Edition ...
Page 93: ...APPENDIX H J1000 CROSSFLOW FAN Part 07EEG Appendix H 1 1998 2006 Edition ...
Page 94: ...APPENDIX I 1 EXHAUST BLOWER ASSEMBLY MODEL J1000 Appendix I 1 1998 2006 Edition ...