Jamesway Incubator Company
Part Name / Description:
Platinum 2.0 Center ECU Support
Instruction #:
JIC-INSTP2-00004
Page
3
of
17
Operation Instruction Title:
Platinum Centre ECU Support
Revision Date: 04/03/2018
Revised By: V. Frail
Revision No. A
Approved By: S. Ditner
Page
3
of
17
JIC-INSTP2-00004 Step 6
Fit the 8 holes in the center stand with
PB5775 7/8” snap bushings.
JIC-INSTP2-00004 Step 7
Install the AB7430 pipe assemblies
through the ECU center support.
Cut 4”
off the two return pipes (the two pipes in
the center).
The longer side of the pipe assembly
should be oriented down through the
bushings, and the shorter side should be
oriented to the top of the center support.
Pipe cutter
JIC-INSTP2-00004 Step 8
Attach the 2x MB20117 front and rear
support plates to the assembly using P314
bolts, PT1195 flat washers and P6395 lock
nuts.
Note:
the longer lip on each plate should
be at the bottom.
Screwdriver
Socket