JIC-INSTP2-00004 Step 21
Cut the PB4590 PVC conduit into two
lengths:
•
57” (145 mm)
•
19” (48 mm)
JIC-INSTP2-00004 Step 22
From the inside, screw the PB4841 PVC
adaptor into the tapped hole in the centre
roof extrusion.
JIC-INSTP2-00004 Step 23
Test fit the PVC conduit into the ECU
stand.
The long pipe should fit snugly into the
roof adaptor with the PB4636 coupling
resting on the top plate of the centre
stand.
The short piece of PVC conduit will come
up through the bottom of the stand in to
the coupling.
Adjust lengths if necessary.