background image

 

10 

Plumbing Connections 

All plumbing connections should be made by a qualified, licensed plumber in accordance with local 

plumbing and building codes. 

Hot and Cold Water Supply Lines 

Connect 1/2” ID supply tubes to a fresh water source. Shut-off valves should be utilized. 

 
Electrical Connections 

The Foot spa must be plugged into a GFCI protected outlet, installed by a licensed electrician. 

 
Testing the Foot spa 

Clean the tub and fill with water to the wave-mark (water level) on the wall of the tub. 

When the tub is filled with water, turn the switch on the front of the pedicure spa to activate the 

whirlpool pump. Water should be coming out of the jets and the Air Bleed spout. Check for whirlpool 

leaks. After checking under the tub for leaks, use the same switch to turn the whirlpool pump off 

and drain the tub basin by opening the overflow/waste control handle and turning on the Power 

Drain Pump if installed. 

 

Cleaning and Care of Your Foot spa 

Between Each Customer 

• Drain all water and remove debris from the pedicure spa. 

• Clean the surfaces and walls of the Foot spa with soap or detergent and rinse with clean, clear 

water 

• Disinfect with an EPA-registered disinfectant. 

• Wipe out with a clean towel. 

 

Flushing of the Whirlpool System 
Caution:

 J&A USA requires that the pedicure spa be thoroughly cleaned after every 10th pedicure 

and after the last pedicure of the day. It is extremely important to flush the whirlpool system of 

the Foot spa to prevent harmful bacteria from growing and to prolong the life of your pedicure spa. 

• Remove the Suction Fitting Cover with a phillips screwdriver 

• Scrub the suction cover with a chlorine bleach solution of 1 (one) teaspoon of 5% chlorine bleach 

to 1 gallon of water, or 

• Totally immerse the suction Fitting cover in an EPA-registered disinfectant and scrub. 

• Replace the Suction Fitting Cover with a screwdriver. Do not over tighten the mounting screw. 

• Do not run the pedicure spa whirlpool jets without the Suction Fitting Cover in place. 

• Fill the tub basin near the wave mark on the rear wall with hot water. 

• Turn the whirlpool jets on. 

• Add 3 (three) teaspoons of low foaming “crystal” dishwasher detergent and 2 (two) ounces of 

household bleach to the tub basin. 

• Run whirlpool for 10-15 minutes and drain the tub basin. 

• Fill the tub basin near the wave mark on the rear wall with cold water. 

• Run the whirlpool jets for 5 minutes and drain the tub basin. 

• Clean the pedicure spa with a soft cloth and a mild detergent. 

 

Weekly Disinfecting Procedure of the Whirlpool System 

• After following the outlined procedures for daily cleaning, fill the pedicure spa tub with hot water 

and 4 (four) teaspoons of 5% bleach solution. 

• Circulate the solution through the whirlpool system for 5-10 minutes. 

• Let the solution sit overnight (at least 6-10 hours). 

• The following morning (before the first customer) run the foot spa for 5 minutes and drain. 

• Follow the procedure “Flushing of the Whirlpool System”. 

Summary of Contents for PETRA 300

Page 1: ...by spas pedicure COLLECTION OWNER S MANUAL...

Page 2: ...3 Important Considerations 4 Identifying Parts Description For Petra 700 500 5 Massage System For Petra 450 350R 350V 300 6 Chair Assembly For Petra 700 500 7 Chair Assemb ly For Petra 450 350R 350V...

Page 3: ...ature is dangerous and should be checked before use Maximum water temperature should not exceed 100 deg F 38 deg C 2 Always enter and exit the Whirlpool Pedicure Spa slowly and carefully 3 Never bring...

Page 4: ...or following states AZ CA IL MN NE NV OR TX WA and WI All PETRA pedicure spa are equipped with factory installed Dual Check Back Flow Preventer Specification Tested and certified to meet ANSI ASSE sta...

Page 5: ...ET PUMP IMPELLER 12 OVERFLOW WASTE KNOB 13 POP UP DRAIN STOPPER 14 LIGHT COVER 15 BACK PANEL 16 ARM REST LEVER 17 BASE SHELL 18 WHIRLPOOL JET 19 MASSAGE REMOTE CONTROL 20 SLIDE RECLINE REMOTE CONTROL...

Page 6: ...T 24V DC 1 2A TRANSFORMER MODEL MKD 57121500 INPUT 120V AC 60Hz OUTPUT 12V DC 1 5A Due to continuous improvements on all our products specifications characteristics packing colors designs are subject...

Page 7: ...COLD HOT STOP CONTINUE REPEAT THIGHMASSAGE AUTO TAP KNEAD U P DOWN MASSAGEWHEELS J A A B FORWARD BACKWARD UP DOWN 1 2 3 4 8 COLD HOT STOP CONTINUE REPEAT THIGHMASSAGE AUTO T A P KNEAD UP DOWN MASSAGEW...

Page 8: ...BOLTS 2 ALIGN FOUR BOLTS WITH FOUR HOLES ON THE CHANNEL FRAME 3 TIGHTEN EACH LOCK NUTS TO SECURE THE CHAIR TO THE BASE PETRA 450 PETRA 300 PETRA 350R 350V PETRA Chair Assembly for 450 350R 350V 300 Wa...

Page 9: ...7L x 28W x 55H 57L x 28W x 48H Capacity All Petra Series 5 gallons Power Source SaniJet 115v 60Hz Whirlpool Pump 0 5HP 115VAC 5 5 Amp 60Hz GFCI protected Plumbing Source Hot Cold Water 0 5 inches Fitt...

Page 10: ...ure of the day It is extremely important to flush the whirlpool system of the Foot spa to prevent harmful bacteria from growing and to prolong the life of your pedicure spa Remove the Suction Fitting...

Page 11: ...stic parts Jet casing can be easily cleaned with a non abrasive anti bacterial cleaner when cleaning the tub shell Warning DO NOT use if you are diabetic have poor blood circulation or if any area of...

Page 12: ...un pump dry 4 Do not relocate pump without prior approval from factory Warning To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times T...

Page 13: ...ulation or if any area of your feet or leg is inflamed or has open wound s Please consult your physician before using if you have any kind of fungal infection s swelling fracture or persistent pain As...

Page 14: ...of injury do not permit children to use this product unless they are closely supervised at all times To reduce the risk of electric shock replace damage cord immediately And Do not use extension cord...

Page 15: ...seconds turn pump off Repeat 10 times If the air is not repleased detach attachment pipe and re attach Quick Tip Use a plunger to release the air lock 2 Pump does not turn on Check the power source C...

Page 16: ...k main on off power switch check fuse s When massage is not functional Lubrication 1 Turn off the main power 1 Open the screws phillip or Open the zippers from the front of the chair 2 Apply lubricati...

Page 17: ...ation or maintenance Any applicable warranty shall not apply to J A that have been improper installation or plumbing remanufactured refurbished misused or tampered with in any way LIMITATION OF WARRAN...

Page 18: ...p replacement too Insert the two tabs of the insert tool into the two notches on the front lens of the light assembly counter clockwise to REMOVE clockwise to INSTALL See figure 1 INSERT TOOL 1 Remove...

Page 19: ...reproduction of the material contained in the Online Certification Directory subject to the following conditions 1 The Guide Information Designs and or Listings files must be presented in their entire...

Reviews: