It is important to select a proper location when mounting your circulation 

fan. You must provide a minimum of 5’ unrestricted air flow on the back 

side of the fan. Failure to provide the space needed for airflow may reduce 

motor life and void the warranty.

1

IS123-11I

J&D Manufacturing • 6200 Hwy 12 • Eau Claire, WI 54701 • 1-800-998-2398 • www.jdmfg.com 

Page 2 of 4

If mounting bracket to structure, verify anchor points are strong enough for 

added weight of bracket and fan. Attach top of bracket to structure with 

(4) washers and (4) screws or bolts with nylock nuts (not provided) suitable 

for your structure. DO NOT attach bracket to or against wall as this will 

not give motor enough unrestricted air flow. 

(For pipe mount instructions 

see page 4.

)

2

Prep motor for use by removing the 2 drain plugs located on the bottom 

(flag mount) side of the motor. Removal of these plugs allows for drainage 

of any moisture that might get inside the motor. DO NOT remove the plugs 

on the top (capacitor) side of motor. Removal of these plugs will void 

warranty and allow dirt and moisture into the motor, reducing the life of 

the motor.

3

4c

4a

4b

Attach fan to bracket. Insert bracket flag in between the motor flags and 

secure using the center holes on the motor flags with (1) 3/8” x 1-1/4 hex 

bolt, (2) 3/8” washers and (1) 3/8” nylock nut as shown in step 4a. Using 

the crescent openings on the motor flags, install the (1) 1/4” x 1- hex bolt, 

(2) 1/4” washers and (1) 1/4” nylock nut as shown in step 4b. Adjust the 

fan to the desired angle and tighten hardware to secure fan angle.

Summary of Contents for BARNSTORMER

Page 1: ...r regular wear and tear J D Manufacturing can repair or replace at our option any product or part of the product that is found to be defective Our warranty applies to materials only and does not include return freight delivery loss or damage to personal property cost of removal or installation any incidental or consequential damages or labor This warranty does not apply to products which are misus...

Page 2: ... wall as this will not give motor enough unrestricted air flow For pipe mount instructions see page 4 2 Prep motor for use by removing the 2 drain plugs located on the bottom flag mount side of the motor Removal of these plugs allows for drainage of any moisture that might get inside the motor DO NOT remove the plugs on the top capacitor side of motor Removal of these plugs will void warranty and ...

Page 3: ...ty Do NOT mount fan with capacitor on the bottom This can cause moisture to build up in the capacitor cap and short out the capacitor Mounting the fan this way will void the warranty Do NOT mount bracket horizontally The included bracket was not designed to be mounted this way and cannot withstand the structural stress caused by the weight and movement of the fan Mounting the bracket and fan this ...

Page 4: ... Mount Brackets VRSBR2 HDG VRSBR3 HDG Pole Mount Bracket VRSBR12 VRSBR13 _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____...