Fig.11

Radio frequency is 105.2 MHZ

Save the present frequency to channel 3 (Save channel) 

or Exchange the frequency form channel 3 to the present (Searching channel)

 

                        

 

I

 is the ON/OFF key for radio and CD

and it is only available in the status of power on. The

first pressing 

 is turning on the radio

the second pressing

 “

 will turn off the radio and turn on

the CD at the same time

and the third pressing“

 

will turn off the radio and CD simultaneous

Ⅱ、

LCD will show present frequency and volume of the radio after turning on the radio

Ⅲ、

In the working of radio, the present radio frequency

 

can be changed by pressing

 “

MIN

”and “

HOUR

Ⅳ、

Pressing the key

 “

SET

 will take out the memorized radio frequency

Pressing the key

SET

  continually will take out the memorized radio frequency from  channels  will be saved at present

channel by pressing this key continually

If none of the channel

 LCD will display “---”

Ⅴ、

Press the key

 “

MEM

 ”

 could memorize the present radio frequency

 Pressing the key

 “

MEM

 continually will memorize the present radio frequency in different channel

 The channel of max is

10

Name of channel is 0-9

Ⅵ、

The volume can be changed by pressing key 

SET

VOL+

”and“

OPEN

11

Operation of Pump

The Button 

, operates pump 1

The Button  

PUMP2

operates  pump 2

The button 

PUMP3

operates pump 3

When Circulation cleaning and heating (including preheating) turn on, circulation pump will be

working automatically.

12

Operation of lasting circulation cleaning

Press the key 

 at any time to turn on or off the lasting circulation cleaning, work mode is like the

preset circulation cleaning.  The surfing pumps and blower work for 30 seconds at every 30 minutes. Ozonizer
works for 15 minutes at every 105 minutes, and repeat in this program.

 Once any surfing pumps or blower pump be start, the ozonizer without working.  The ozonizer can not

work if the circulation pump is without working.

 

IMPORTANT

: Please ensure that the ozone function is not in use whilst bathing in the spa.

13

Operation of spa lights

Press the

 “

” button to 

control the ON/OFF of the LED lights and the Fiber optic lights.

14

Setting the constant Temperature Settings

1

)、

Pressing the

 “

 button 

will start the constant temperature heating.

9

Summary of Contents for SPA-565

Page 1: ...HOT TUB Model SPA 565 OPERATING INSTRUCTION 1...

Page 2: ...ower On off or Switch Volume down Open Spa Light On off MEM Radio channel Memory Lock Surfing pump 1 On off SET Radio channel read Close Surfing pump2 On off Lasting Circulation Cleaning On off Surfin...

Page 3: ...ircuit display 1 When you first start the spa the backlight will be dimmed and the LCD will show the current time and temperature If there is a problem with the circuit board the controller will displ...

Page 4: ...5 Circulation cleaning off Fig 6 Circulation cleaning on When setting the Circulation cleaning the display must be in the Power off status and the LCD display 1 Press to enter Circulation cleaning set...

Page 5: ...each time The maximum working time is 19hours and 55 minutes When you have completed this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the s...

Page 6: ...res whether pre heating settings are set or not See following Fig 7 8 ON OFF Fig 7 Pre heat On 8 Pre heat Off Pre heating is set when the spa is in the Power off status and the LCD display shows 1 Set...

Page 7: ...ress SET VOL again It will show SET on the LCD panel Press button to change the setting temperature The range of temperature setting is 15 40 5 When everything is set correctly press the to confirm th...

Page 8: ...the countdown time All the surfing pumps and blower will work for 30 seconds at every 30 minutes The Ozone works at every 15 minutes During the preheating the Circulation cleaning will be turned off...

Page 9: ...ill memorize the present radio frequency in different channel The channel of max is 10 Name of channel is 0 9 The volume can be changed by pressing key SET VOL and OPEN 11 Operation of Pump The Button...

Page 10: ...pa is on normal power supply IV Electric parameters 1 Performance index Rated voltage 220V 50Hz Maximum working current 60 A 220V 240V Voltage resistance 1250V 1 minute without penetration Isolative r...

Page 11: ...potential bonding is carried out WAR NING 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit lnterrupter 2 Grounding is required The unit should be installed...

Page 12: ...3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug of the temperature detector be...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Reviews: