a  Perch  Bar  option.  If  this  cannot  be  achieved  in  the  crosswise  direction,  consider  a  different 
layout or using packing pieces to ensure the specification can be met. 

During assembly: 

 

If necessary drill holes into the base of the JLX-LITE-MkII as required. 

 

Use 20mm (minimum diameter) mud washers under the head of each fixing. 

 

If  using  Nylocks  ensure  the  thread  is  fully  engaged  in  the  nylon.  If  Nylocks  are  not  used,  use 
lock washers under each nut. 

 

Wall plugs should not be used. 

 

The mains outlets are available on one side of the base only. It is recommended the mains out-
let side of the bar face away from the audience view if possible.  

Two  or  more  JLX-LITE-MkIIs  may  be  mounted  end  to  end  to  create  one  longer  bar.  A  single  joining 
spigot is supplied with each JLX-LITE-MkII to end-align these bars. The spigot is not intended to carry 
any significant load and should not be used in lieu of fixings in the base. 

 

2.3

 

Planning - Electrical 

 

The JLX-LITE-MkII is supplied with unwired/loose mains sockets that can be configured during installa-
tion. Some options include: 

 

One circuit for all outlets.  This is more suited to small  installations or  where no  dimming is re-
quired  -  the  outlets  are  used  to  power  non-dim  equipment  such  as  LED  fixtures  and  moving 
lights. 

 

Each supply circuit feeding a small number of outlets - for example one circuit feeding two out-
lets.  Circuits  may  run  direct  to  a  switchboard  or  to  a  patch  panel  if  dimming  may  be  required. 
This is suited to intermediate installations.  

 

Individual circuits wired to a patch panel. This is the most flexible arrangement allows circuits to 
be used as dimmers or direct power at will. 

The mains outlets are available on one side of the base only. It is recommended the mains outlet side of 
the bar face away from the audience view. 

The  JLX-LITE-MkII  includes  a  number  of  knockouts  and  holes  in  the  mounting  face  and  ends  of  the 
base.  If  the  wiring  can  be  planned  before  mounting  it  will  be  easier  to remove  the  required  knockouts 
while the JLX-LITE-MkIIs are on the floor, prior to mounting. If the wiring hasn't been planned or there is 
doubt about the how it will be done, they should be left in place for removal by the Electrician during in-
stallation. 

 

2.4

 

Installation 

The following is the installation procedure for horizontal bars. If mounting the JLX-LITE-MkII at an angle 
greater than about 6 degrees lengthwise, use the Perch Bar option. Refer to section 2.5. It is intended 
that the JLX-LITE-MkII be installed with the bar in place. 

1.  Install the supporting structure. See the available options and notes in section 2.2. 

2.  Remove the dress covers by removing the screw and sliding the cover along the bar enough so 

it can be angled out of the available gap between the bar supports. Put the covers and screws 
to the side with the other supplied accessories 

Summary of Contents for JLX-LITE-MkII

Page 1: ...Modular Lighting Bar System JLX LITE MkII USER GUIDE ...

Page 2: ... repairs on this product be carried out by JANDS Pty Ltd or its authorised service agents JANDS Theatre equipment must only be used for the purpose they were intended by the manufacturer and in conjunction with this user guide JANDS Pty Ltd will not accept any liability whatsoever for any loss or damage caused by service maintenance or repair by unauthorised personnel or by use other than that int...

Page 3: ... 2 3 Planning Electrical 4 2 4 Installation 4 2 5 Perch Bar Vertical Installation 6 2 6 Installation Record 8 3 INSPECTION MAINTENANCE 9 3 1 Annual Equipment Inspection Maintenance Log 10 4 TECHNICAL DATA AND SPECIFICATIONS 11 4 1 Rated Capacity 12 4 1 1 Definitions of Load 12 4 1 2 Maximum Point Load 12 4 1 3 Maximum Uniformly Distributed Load UDL 12 4 2 Mounting Hole Detail 13 ...

Page 4: ...ncluding Surface mounted to ceiling On a surface mounted frame Suspended from threaded rods Vertical mounting as a Perch Bar The Jands JLX LITE MkII is suitable for fixed indoor applications only and is not protected against the ingress of moisture The JLX LITE MkII is not rated as a lifting bar under AS4991 The JLX LITE MkII is supplied unwired and the wiring should be installed by a licensed ele...

Page 5: ...f the JLX LITE MkII must be mounted against a suspended ceiling it should be mounted to the struc ture above the ceiling using droppers Fixed using standard strut or other additional dedicated structure mounted either along the bar or preferably perpendicular to the bar for example surface mounted standard strut Do not mount the JLX LITE MkII using plasterboard fasteners of any kind the JLX LITE M...

Page 6: ... a small number of outlets for example one circuit feeding two out lets Circuits may run direct to a switchboard or to a patch panel if dimming may be required This is suited to intermediate installations Individual circuits wired to a patch panel This is the most flexible arrangement allows circuits to be used as dimmers or direct power at will The mains outlets are available on one side of the b...

Page 7: ...ide 8 Run and terminate the mains wiring The Jands JLX LITE MkII is supplied as a wiring enclosure for installation by a licensed electrician to AS NZS 3000 wire links are supplied to earth the socket outlets to a nearby tab on the chassis Bend the tabs inwards before fitting the earth link wire 9 If using the ELV compartment run and terminate the low voltage wiring then fit wire the con nectors 1...

Page 8: ...nt the Perch Bar option at the low end of the bar When correctly installed the Perch Bar option allows the JLX LITE MkII bar to be used at the rated working load limit Note at high bar angles the bar will transfer the bulk of the load to the supporting structure via the Perch Bar mount at the bottom Hence this mount must be well fixed to the supporting structure using multiple solid anchors that i...

Page 9: ...iring then fit wire the con nectors 11 Check the Earth continuity of all external parts and the socket outlet Earths 12 Test the wiring as required by AS NZS 3000 13 Load test the bar 14 Check the fixings are all in tact and none have significantly deformed as a result of the load test At the same time double check all fasteners are secure and are using load spreading washers Also check there is a...

Page 10: ... person installing the lighting bar s Where more than one person has installed the lighting bar s the foreman supervisor or similar person responsible for the works should fill out and sign this record Product JANDS JLX LITE MkII Number of Bars Serial Number s Project Name Job No Installed By Company Comments Name Signature Date ...

Page 11: ...be carried out annually on both the mechanical structure and the electrical wiring etc by appropriately qualified persons Fill out the serial numbers for the inspection maintenance logs then copy the pages for future use All the records should be kept for future reference WARNING The JLX LITE MkII should be regularly inspected by an ap propriately qualified person s ...

Page 12: ... outlets for evidence of wear and damage Inspect mains cable and plugs for evidence of wear and damage Inspect all screws nuts bolts for correct tightness and physical integrity Inspect the visible portions of the central extrusion for distortion or cracks Inspect attachment clamps brackets and standoffs for distortion or damage Perform safety tests test tag to AS3760 Comments Name Signature Test ...

Page 13: ...istributed Load in cluding any point loads in a given span 50kg m Working Load Limit 100kg 150kg Total Torsional Load on bar 10Nm 15Nm Bar Length 1600mm 2400mm Depth 147mm Height 207mm Net Weight 9kg 12kg Ingress Protection IP2X Specification only valid when the top face of the duct is horizontal in both the crosswise and longitudinal directions This specifi cation is reduced when the JLX LITE MKI...

Page 14: ...that the bar is permitted to carry It is made up of a combination of point loads and distributed loads 4 1 2 Maximum Point Load This is the maximum individual load that can be applied to a JLX LITE MkII An example would be a single light attached to the Bar Figure 4 1 Point Load In addition the sum of all point loads between two bar hangers must not exceed the specified maxi mum 4 1 3 Maximum Unif...

Page 15: ...USG 00000 JLXLITEMKII 1 0 JLX LITE MKII 13 4 2 Mounting Hole Detail ...

Reviews: