USG-00000-JLXLITEMKII [1.0]

 

 

 

JLX LITE MKII 

 

 

 

5.  Depending on the required configuration it may be possible to install some of the wiring before 

the bar has been hung. If this is the case, install any wiring that can be installed now.  

6.  Fit the JLX-LITE-MkII to the Perch Bar mount so that the bar slides over the integral spigot on 

the mount. Ensure the bar slides all the  way down and  is resting  against the mount. If the bar 
does not rest against the mount, rectify the problem.  

7.  Fix  the  first  JLX-LITE-MkII  base  to  the  supporting  structure,  checking  the  orientation  of  the 

mains outlets.  

8.  If  desired  a  second  Perch  Bar  mount  can  be  installed  at  the  top  of  the  bar  to  provide  greater 

stability. 

9.  Run and terminate the mains wiring. The Jands JLX-LITE-MkII is supplied as a wiring enclosure 

for  installation  by  a  licensed  electrician  to  AS/NZS  3000  -  wire  links  are  supplied  to  earth  the 
socket outlets to a nearby tab on the chassis. Bend the tabs inwards. 

10.  If using the ELV compartment, run and terminate the low voltage wiring, then fit / wire the con-

nectors.  

11.  Check the Earth continuity of all external parts and the socket outlet Earths. 

12.  Test the wiring as required by AS/NZS 3000. 

13.  Load test the bar. 

14.  Check  the  fixings  are  all  in-tact  and  none  have  significantly  deformed  as  a  result  of  the  load 

test.  At  the  same  time  double  check  all  fasteners  are  secure  and  are  using  load  spreading 
washers. Also check there is an adequate quantity of fasteners (minimum one per bar hanger) 
and the distribution of the fixings is even across the base/s.  If necessary, add more fixings. 

15.  Cable tie the mains cable to the anchor points provided. 

16.  Cover any unused low voltage ELV connector knockouts with the supplied blank stick-on labels, 

and similarly apply the numerical labels next to the mains sockets. Apply the numbers so they'll 
be able to be seen through the cut-out in the dress cover when fitted - use the earth tab next to 
the  socket  as  a  locating  guide.  Unused  mains  socket  holes  must  be  protected  with  a  metal 
cover. 

17.  Remove the clear protective coating from the covers. 

18.  Fit the covers. The covers must be secured using the screws provided. 

19.  Fit the supplied end plugs to any open ends of the bar. 

20.  Fill out the installation record. 

 

Summary of Contents for JLX-LITE-MkII

Page 1: ...Modular Lighting Bar System JLX LITE MkII USER GUIDE ...

Page 2: ... repairs on this product be carried out by JANDS Pty Ltd or its authorised service agents JANDS Theatre equipment must only be used for the purpose they were intended by the manufacturer and in conjunction with this user guide JANDS Pty Ltd will not accept any liability whatsoever for any loss or damage caused by service maintenance or repair by unauthorised personnel or by use other than that int...

Page 3: ... 2 3 Planning Electrical 4 2 4 Installation 4 2 5 Perch Bar Vertical Installation 6 2 6 Installation Record 8 3 INSPECTION MAINTENANCE 9 3 1 Annual Equipment Inspection Maintenance Log 10 4 TECHNICAL DATA AND SPECIFICATIONS 11 4 1 Rated Capacity 12 4 1 1 Definitions of Load 12 4 1 2 Maximum Point Load 12 4 1 3 Maximum Uniformly Distributed Load UDL 12 4 2 Mounting Hole Detail 13 ...

Page 4: ...ncluding Surface mounted to ceiling On a surface mounted frame Suspended from threaded rods Vertical mounting as a Perch Bar The Jands JLX LITE MkII is suitable for fixed indoor applications only and is not protected against the ingress of moisture The JLX LITE MkII is not rated as a lifting bar under AS4991 The JLX LITE MkII is supplied unwired and the wiring should be installed by a licensed ele...

Page 5: ...f the JLX LITE MkII must be mounted against a suspended ceiling it should be mounted to the struc ture above the ceiling using droppers Fixed using standard strut or other additional dedicated structure mounted either along the bar or preferably perpendicular to the bar for example surface mounted standard strut Do not mount the JLX LITE MkII using plasterboard fasteners of any kind the JLX LITE M...

Page 6: ... a small number of outlets for example one circuit feeding two out lets Circuits may run direct to a switchboard or to a patch panel if dimming may be required This is suited to intermediate installations Individual circuits wired to a patch panel This is the most flexible arrangement allows circuits to be used as dimmers or direct power at will The mains outlets are available on one side of the b...

Page 7: ...ide 8 Run and terminate the mains wiring The Jands JLX LITE MkII is supplied as a wiring enclosure for installation by a licensed electrician to AS NZS 3000 wire links are supplied to earth the socket outlets to a nearby tab on the chassis Bend the tabs inwards before fitting the earth link wire 9 If using the ELV compartment run and terminate the low voltage wiring then fit wire the con nectors 1...

Page 8: ...nt the Perch Bar option at the low end of the bar When correctly installed the Perch Bar option allows the JLX LITE MkII bar to be used at the rated working load limit Note at high bar angles the bar will transfer the bulk of the load to the supporting structure via the Perch Bar mount at the bottom Hence this mount must be well fixed to the supporting structure using multiple solid anchors that i...

Page 9: ...iring then fit wire the con nectors 11 Check the Earth continuity of all external parts and the socket outlet Earths 12 Test the wiring as required by AS NZS 3000 13 Load test the bar 14 Check the fixings are all in tact and none have significantly deformed as a result of the load test At the same time double check all fasteners are secure and are using load spreading washers Also check there is a...

Page 10: ... person installing the lighting bar s Where more than one person has installed the lighting bar s the foreman supervisor or similar person responsible for the works should fill out and sign this record Product JANDS JLX LITE MkII Number of Bars Serial Number s Project Name Job No Installed By Company Comments Name Signature Date ...

Page 11: ...be carried out annually on both the mechanical structure and the electrical wiring etc by appropriately qualified persons Fill out the serial numbers for the inspection maintenance logs then copy the pages for future use All the records should be kept for future reference WARNING The JLX LITE MkII should be regularly inspected by an ap propriately qualified person s ...

Page 12: ... outlets for evidence of wear and damage Inspect mains cable and plugs for evidence of wear and damage Inspect all screws nuts bolts for correct tightness and physical integrity Inspect the visible portions of the central extrusion for distortion or cracks Inspect attachment clamps brackets and standoffs for distortion or damage Perform safety tests test tag to AS3760 Comments Name Signature Test ...

Page 13: ...istributed Load in cluding any point loads in a given span 50kg m Working Load Limit 100kg 150kg Total Torsional Load on bar 10Nm 15Nm Bar Length 1600mm 2400mm Depth 147mm Height 207mm Net Weight 9kg 12kg Ingress Protection IP2X Specification only valid when the top face of the duct is horizontal in both the crosswise and longitudinal directions This specifi cation is reduced when the JLX LITE MKI...

Page 14: ...that the bar is permitted to carry It is made up of a combination of point loads and distributed loads 4 1 2 Maximum Point Load This is the maximum individual load that can be applied to a JLX LITE MkII An example would be a single light attached to the Bar Figure 4 1 Point Load In addition the sum of all point loads between two bar hangers must not exceed the specified maxi mum 4 1 3 Maximum Unif...

Page 15: ...USG 00000 JLXLITEMKII 1 0 JLX LITE MKII 13 4 2 Mounting Hole Detail ...

Reviews: