Page 14
ENGLISH
AquaLink
®
RS OneTouch™ | Owner’s Manual
3.5.3 MAINTAIN TEMP
SYSTEM SETUP
MENU/HELP
Select to set how often the water
temperature is sampled with the
MAINTAIN TEMP feature is
active.
• The default setting for two (2)
hours.
• Sampling interval can be set to
one (1), two (2) or four (4) hours.
3.5.4 FREEZE PROTECT
SYSTEM SETUP
MENU/HELP
Select to set the temperature for
the FREEZE PROTECT function
and to assign which equipment
will activate when freezing
conditions are detected.
• Freeze protected equipment
will turn ON when freezing
conditions are detected.
• Activation temperature can be
adjusted between 34°F and 42°F.
• Default activation temperature
is 38°F, and deactivation
temperature is within 2°F.
WARNING
Freeze protection is intended to protect equipment and plumbing for short
periods of freezing only. It does this by activating the filtration pump and
circulating the water to prevent freeze inside equipment or plumbing.
Freeze protection does
not
guarantee that equipment will not be damaged
by extended periods of freezing temperatures or power outages. In these
conditions, the pool and spa should be shut down completely (e.g. drained
of water and closed for the winter) until warmer weather exists.
More
System Setup
Spa Link
Dusk Setup
All Off Time
Clear Memory
Device Runtime
Maintain Temp
Onetouch
Product Info
Maintain Temp
Setup
Measure Water
Temperature
Every: 2 Hrs.
Use ARROW KEYS
to set value.
Press SELECT
to continue.
System Setup
OneTouch
Label Aux
Freeze Protect
Air Temp
Degrees C/F
Temp Calibrate
In Floor Clean
More
AquaPure
Freeze Protect
Use ARROW KEYS
to set value.
Press SELECT
to continue.
Temp
38°F
Filter Pump
X
Spa
Solar Heat
Rockfall
More
Freeze Protect
Devices