Page 22
ENGLISH
AquaLink
®
RS OneTouch™ | Owner’s Manual
4.3.3.(D) MIN-MAX SETTINGS
SYSTEM SETUP
MENU/HELP
MIN-MAX SETTINGS
VAR SPEED PUMP
Select to set a minimum and
maximum global speed or flow.
•
Scale is fixed at RPM for:
Jandy
®
ePump™ DC,
IntelliFlo
®
VS, IntelliPro
®
VS.
•
Scale is fixed at GPM for:
IntelliFlo VF
4.3.3.(E) SPEED/LABELS
SYSTEM SETUP
MENU/HELP
SPEED/LABELS
VAR SPEED PUMP
4.3.3.(E-1) SET SPEEDS
Select to set and/or edit the
speeds for various pool functions.
There are 8 default preset labels
depending on your equipment
configuration. Each label can
also be changed, new labels can
be selected from a general list or
custom entry.
Default Speed Labels
for Combo or Pool/Spa only
Default
Pool/Spa
Only
Pool/Spa
Combo
1
POOL
POOL
2
SPEED 2
SPA
3
*
SPEED 3
*
SPEED 3
4
**
SPEED 4
**
SPEED 4
5
TEMP 1
POOL HEAT
6
TEMP 2
SPA HEAT
7
***
SPEED 7
***
SPEED 7
8
INFLOOR
INFLOOR
*CLEANER will display if dip S1-1 is on
**SPILLOVER will display if dip S1-3 is on
***SOLAR HEAT will display if dip S1-7 is on
***HEATPUMP will display if dip S2-7 is on
Min Limit 600
Pump Application
Pump 1
Pump 2
Pump 3
Highlight an
Item and press
SELECT
Pump 4
Scale Rpm
Max Limit 3450
Highlight an
Item and press
SELECT
Min-max Settings
Pump 1
Speeds/Labels
Pump 1
Pump 2
Pump 3
Highlight An
Item And Press
SELECT
Speed/Labels
Pump 1
Label Speeds
Assign Speeds
Set Speeds
Highlight An
Item And Press
SELECT
Set Speeds
Pump 1
Pool
Spa
Speed3
Speed4
Pool Heat
Spa Heat
Solar Heat
1725
2750
2750
2750
2250
2250
2750
Adjust Pool
(Rpm)
Pool
1725
Highlight An