Page 46
ENGLISH
AquaLink
®
RS OneTouch™ | Owner’s Manual
6.2 SPECIAL AUXILIARY LABELS
Air Blower
When an AUX button labeled “Air Blower” is pressed, it will turn on the air
blower for 30 minutes, then automatically turn it off. An air blower may be programmed
like any other auxiliary, except that you can program only the ON time. The air blower
will turn on at the programmed ON time, and turn off 30 minutes later. This is to protect
the blower motor from overheating during extended operation. To change the ON
time from the default value of 30 minutes, refer to the DEVICE RUNTIME feature.
Extra AUX
System features (for example, light dimming, software labeling, and timed aux)
can be assigned to the extra AUX button. Only freeze protection cannot be assigned
to the extra auxiliary.
Fill Line
When an AUX button labeled “Fill Line” is pressed, it will turn on the fill line
for 30 minutes, and then automatically turn it off. A fill line may be programmed like
any other auxiliary, except that you can program only the ON time. The fill line will
turn on at the programmed ON time, and turn off 30 minutes later. This is to avoid
overfilling the pool. Choose the appropriate number of “fill” programs during the week
to keep your pool at the appropriate level. To change the ON time from the default
value of 30 minutes, refer to the DEVICE RUNTIME feature.
Spare AUX
With DIP Switch S1-6 turned OFF, the spare auxiliary socket is energized in
“Pool Mode” and off in “Spa Mode”. With DIP Switch ON, the spare Auxiliary socket
is energized in the “Spa Mode” and off in the “Pool Mode”. Operates only with Pool/
Spa combination units.
6.3 CONTROLLER MESSAGES
CLEANER CANNOT BE TURNED ON WHILE SPA IS ON
This message is
displayed if the pool cleaner is activated when in spa mode (i.e., water is circulating
to spa). The pool cleaner requires that water be circulating to the pool in order for it
to operate. Return to pool mode to activate the cleaner.
CLEANER CANNOT BE TURNED ON WHILE SPILLOVER IS ON
The return
valve has been rotated to the spa position to give the spa spillover effect.
FREEZE PROTECT
This message indicates that freezing conditions have been detected
by the freeze protection sensor, and that equipment assigned to freeze protection (e.g.,
filter pump) are active. See the Section “3.5.4 Freeze Protect”, for more information.
NOTE
Only the filter pump is protected unless the optional freeze
sensor is installed. If a freeze protected Auxiliary is turned off during
freeze protection, a message will be displayed indicating that item
is off but will turn on in X amount of minutes. The minutes will vary
depending on how long freeze mode has been active from 1 to 15
minutes.
POOL HEATER ENABLED
This message indicates that the pool heater is ready to use
but is not actually firing. The filter pump must be on, and the water temperature must
be below the setting for the heater to fire.
PUMP WILL REMAIN ON WHILE SPILLOVER IS ON
This message is displayed
when you attempt to turn off the filter pump while a spa spillover is on. Since the
filter pump is necessary for spillover operation, the pump will remain on until the
spillover is turned off.