9. Connect the DC cord to the power center. Feed the DC cord through the same strain relief fitting as the
flow/temp/salinity sensor
. Plug the DC cord into the two spade connectors of the wiring harness located
in the low voltage raceway of the control/power center, see Figure 2a, 2b, and 2c. This wiring harness
establishes the connection between the cell and the power interface PCB.
10. Tighten strain relief fitting screws for the flow/temp/salinity sensor
and the DC cord.
Do not pull
Flow/Temp/Salinity Sensor cable or DC Cord too tight. Allow a little slack for the cable inside of
power center enclosure.
CAUTION
Do not over tighten the strain relief fitting. Over tightening can cause damage to the flow/temp/salinity
sensor cable.
11. Prior to reattaching front cover, check the wiring. Be sure the
flow/temp/salinity sensor
is plugged in.
The DC cord should be plugged in. Also, check the AC wiring.
12. Plug one end of the ribbon cable into the back of the user interface and the other end into the J1
connector on the power interface PCB (see Figures 2a, 2b, 2c, and 10).
WARNING
To avoid property damage, serious injury or death, do not operate the electrolytic cell without water
circulation. A buildup of flammable gases can result in FIRE or EXPLOSION.
3.7.2
Replacement of Existing 3-Port Cell (Universal or 2” PVC Unions)
1. Be sure pool pump is turned off.
2. Unplug DC cable from existing cell. Disconnect the DC cord from the wiring harness as shown in
Figure 2a, 2b, and 2c. Loosen the strain relief fitting that also contains the cable for flow/temp/salinity
sensor. Pull the DC cord out through the strain relief.
CAUTION
Do not allow the DC Cord to pull too tightly on flow/temp/salinity sensor cable as it is being pulled
through the strain relief. This may damage the flow/temp/salinity sensor cable and its connection to the
printed circuit board.
3. Remove flow/temp/salinity sensor from cell by unscrewing coupling nut on sensor port. The sensor
should pull straight out after nut is removed.
4. Remove old 3-port cell body by unscrewing coupling nuts on flow ports. The cell body will be free to
pull out after nuts are clear of the threads.
5. Replace existing union o-rings with new o-rings provided with cell kit.
6. Install new cell and tighten coupling nuts.
7. Install the flow/temp/salinity sensor into the available sensor port (See Figure 11).
8. Plug the new DC cord provided with the cell kit, in either direction, into the cell stud terminals
protruding from the cell top. Make sure that the plug is fully inserted and bottomed out on the housing.
CAUTION
To avoid risk of damage to the equipment and possible injury, it is important to make sure the DC cable
connector is fully seated on the cell stud terminals.