9. Connect the DC cord to the control center. Feed the DC cord through the same strain relief fitting as
the flow/temp/salinity sensor. Plug the DC cord into the two spade connectors of the wiring harness as
shown in Figures 2a, 2b, and 2c.
CAUTION
Do not bury the electrolytic cell DC cord or sensor cable directly in the ground. Direct burial can cause
damage to an electrical cord/cable.
10. Tighten strain relief fitting screws for the flow/temp/salinity sensor cable and the DC cord.
Do not
pull flow/temp/salinity sensor cable or DC Cord too tight. Allow a little cable slack inside of control
center enclosure.
CAUTION
Do not over tighten the strain relief fitting. Over tightening can cause damage to the flow/temp/salinity
sensor cable.
11. Check the wiring prior to reattaching front cover. Be sure the flow/temp/salinity sensor is plugged in.
The DC cord should be plugged in. Also, check the AC wiring.
12. If disconnected, plug the ribbon cable into the J1 connectors the user interface and the Power Interface
PCB (See Figures 2a, 2b, 2c, and 10).
WARNING
To avoid property damage, serious injury or death, do not operate the electrolytic cell without water
circulation. A buildup of flammable gases can result in FIRE or EXPLOSION.
3.7.3 Replacement of old 2-Port (Square) Cell with new 3-Port Cell
1. Be sure pool pump is turned off.
2. Unplug DC cable from existing cell. Disconnect the DC cord from the wiring harness as shown in
Figure 2a, 2b, and 2c. Loosen the strain relief fitting that also contains the cable for flow/temp/salinity
sensor. Pull the DC cord out through the strain relief.
CAUTION
Do not allow the DC Cord to pull too tightly on flow/temp/salinity sensor cable as it is being pulled
through the strain relief. This may damage the flow/temp/salinity sensor cable and its connection to the
printed circuit board.
3. Please choose one of the following options (See Table 1):
3a. Option 1 - Retain Existing Sensor in Threaded Tee
3b. Option 2 - Install New Sensor in 3rd Port of Cell (remove old sensor and plug tee)
3c. Option 3 - Replace Section of Piping (eliminate old cell and sensor fittings) and treat as New Installation
2-Port Cell
Thread Size and Style
Option 1
Option 2
Option 3
2" PVC Male (black)
Yes
Yes
Yes
1.5" ABS Female (White "Hayward
®
" Style)
No
No
Yes
Table 1.
Option Selection Tool
Page 19
ENGLISH
Page 19
ENGLISH
Jandy
®
AquaPure
®
/PureLink™ Power Center and Cell Kit
|
Installation and Operation Manual