5.1 User Interface Controls
Chlorine
Production Rate
Adjustment
Pressing the down arrow button
A
or the up arrow button
B
will change the
CHLORINE PRODUCTION RATE
in 5% increments. Generally, adjustments to
production should be made in 10% increments.
In
the PureLink system, adjustments to the chlorine production rate can be made
from either the AquaLink
®
RS control panel or from the power center user interface.
Salinity
Press the
SALINITY
button
C
to check the salinity of the water in pool.
Boost
Press and hold the
POOL TEMP -BOOST-
button
D
for 10 seconds to enter the
Boost
mode (Note ‘
bo
’ will flash intermittently).
Boost
can be used to set chlorine
production to maximum (100%) for 24 hours of operation. After 24 hours of
chlorinator run time, chlorine production will return to previous setting. To clear
the
Boost
mode, press and hold the
POOL TEMP -BOOST-
button
D
again for 10
seconds.
NOTE
When a pool pump timer is used to limit chlorinator run time, the 24 hours
will only count down when the chlorinator is on.
Temperature
Press the
POOL TEMP -BOOST-
button
D
to check the pool water temperature.
Temperature measurements can be displayed in either Fahrenheit or Celsius. For
more information, see
Section 8
,
Temperature Conversion.
Section 5.
Operating Instructions
NOTE
The user interface is located inside the control/power center. To access the control panel, open the door to the
control/power center. See Figure 18.
Figure 18. User Interface
Page 31
ENGLISH
Page 31
ENGLISH
Jandy
®
AquaPure
®
/PureLink™ Power Center and Cell Kit
|
Installation and Operation Manual