CELL REVERSING
The
automatic cleaning cycle is in progress. The cleaning cycle is factory set and
cannot be adjusted. Cell Reversing does not interrupt the production of chlorine.
SALINITY
Salinity
is displayed along with the
gpl
(grams per liter) indicator, when the
SALINITY
button
(C)
is depressed. If a reading of
HH
appears, the salinity is above
4.5 to 6.5 gpl (depending on pool temperature) and is too high to measure correctly
(at normal temperatures). Maintain salinity between 3.0 and 3.5 gpl. See
Section 4
.
ADD SALT
The
ADD SALT
indicator comes on when the flow/temp/salinity sensor determines
that the salinity level of the pool water is too low. Maintain Salinity between 3.0
and 3.5 gpl.
SERVICE and
Service Code
The
SERVICE
indicator will turn on whenever the control system detects a problem
that requires attention. The
SERVICE
indicator is accompanied by a service code
displayed on the front panel, displayed as a 3 digit code. The service code(s) are
displayed twice per minute with an audible alarm.
NOTE
See
Section 7.2, Service Codes
. Problems can range from insufficient salinity to the DC cord not connected.
Audible Alarm
An
audible alarm (beep) sounds once per hour, and only for the first service code,
when a
SERVICE
condition is detected. The alarm can be cleared by pressing and
holding the
SALINITY
button
(C)
for 5 seconds. The audible alarm can be cleared
for 24 hours or until the power to the unit is turned off and back on whichever
comes first. However, the audible alarm will return if a new problem is detected.
NOTE
The audible alarm can be permanently disabled by removing the jumper from J2 on the control/power center
Power Interface Board (PIB).
Audible Alarm
Volume Control
Audible
alarm operation and volume control can be adjusted. To adjust volume
control, press and hold the
TEMPERATURE
button
(D)
for 15 seconds. The system
will beep once when pressed, once after 10 seconds and once after 15 seconds.
Release the key after the third beep. Press the
SALINITY
button
(C)
within 5
seconds to enter the temperature change screen.
NOTE
The boost cycle is normally activated after 10 seconds, however, if the key is held
down until after the third beep at 15 seconds, the Boost mode will not be changed.
The
system will display a ‘1’ followed by ‘F’ or ‘C’. Press the
TEMPERATURE
button
(D)
to move to the second parameter screen. The screen will display a 0, and
the alarm volume will be fully reduced. The system will occasionally show a ‘2’ to
display the screen number. Press the arrow button B to increase the volume and the
arrow button A to reduce the volume. The volume increments from 0 to 100 in 20
steps. After each press of the arrow buttons, the alarm will activate to demonstrate
the current volume level. When the alarm volume has been adjusted to the desired
setting, press the
SALINITY
button
(C)
to confirm the new alarm volume setting.
The change will be stored in permanent memory. If you do not wish to keep the
change, wait 5 seconds, and the change screen will ‘time out’ and return to normal
operation without keeping any changes to the system. Any changes made to the
alarm volume will NOT be saved if this occurs.