This message is displayed if the pool cleaner is activated
when in spa mode (i.e., water is circulating to spa). The pool cleaner requires that water be circulating to the pool in order for it to
operate. Return to pool mode to activate the cleaner.
The return valve has been rotated to the spa position
to give the spa spillover effect.
This message indicates that freezing conditions have been detected by the freeze protection sensor,
and that equipment assigned to freeze protection (e.g., fi lter pump) are active. See the Section 7.4, Freeze Protection, for more
information.
This error message indicates that the sensor is not installed properly or is malfunctioning. Call your pool
service person to resolve this problem.
This message indicates that the pool heater is ready to use but is not actually fi ring. The fi lter
pump must be on, and the water temperature must be below the setting for the heater to fi re.
This message is displayed when you attempt to turn off the fi lter
pump while a spa spillover is on. Since the fi lter pump is necessary for spillover operation, the pump will remain on until the
spillover is turned off.
This message indicates that the fi lter pump is circulating water to
cool down the heater. The fi lter pump will continue to run for fi ve minutes to protect the heater from damage, whenever the heater
has fi red and has been off for less than fi ve (5) minutes.
This message is displayed during pool/spa switching. The AquaLink
®
RS waits 35
seconds while the valves turn from pool position to spa position (or vice-versa) before activating the fi lter pump.
This message indicates that the Controller has been locked out from the power center and is not operational.
Service mode is used by the pool service person to aid them in servicing the pool. The Controller will not be functional until the
switch at the Power Center is moved back to AUTO mode.
This error message indicates that the sensor is not installed properly or is malfunctioning. Call your pool
service person to resolve this problem.
When the system is in Spa Mode (water is circulating to the spa) and
the Spa button is pressed to switch water circulation to the pool, the system will not switch to Pool Mode for fi ve minutes, and
will continue to circulate the water (if the heater has fi red and has been off for less than fi ve minutes). This delay allows water to
cool the heater down by circulating water through it, preventing equipment damage.
This message indicates that a timed auxiliary (usually a blower)
has been activated and will turn off after 30 minutes. Some labels (e.g., blower, fi ll line) have a built-in 30 minute shut off.
This message indicates that the Controller has been locked out from the Power Center and is not operational.
TIME OUT mode is used by the pool service person to aid them in servicing the pool. The Controller will not be functional for
three hours, or until the switch at the Power Center is turned back to AUTO mode.
This message is displayed when the spa spillover is pressed while in spa mode
(water circulation is to spa). The spillover requires that water circulation is to pool in order to operate. The spillover will activate
when the system switches back to pool mode.