NOTE
The filter pump is always protected; spa and auxiliary circuits can be assigned to freeze protection. If a freeze protected
Auxiliary is turned off during freeze protection, a message will be displayed indicating that item is off but will turn on in X
amount of minutes. The minutes will vary depending on how long freeze mode has been active from 1 to 15 minutes.
NOTE
If the message reads WATER TEMP OPEN, the heater will not fire. If message AIR TEMP OPEN is displayed, freeze
protection will not operate correctly.
NOTE
If the message reads WATER TEMP SHORT, the heater will not fire. If the message AIR TEMP SHORT is displayed,
freeze protection will not operate correctly.