background image

Page 8

4.  Re-install the cover for the battery chamber 

and secure with the two (2) screws removed 

in Step 2.

3.4 

Changing the Frequency Channel

If your AquaLink RS AquaPalm system is turning 

items  on  or  off  at  undesignated  times,  another 

AquaLink  RS AquaPalm  system  may  be  in  close 

proximity  using  the  same  or  similar  frequency 

channel. To prevent unwanted operation the channel 

for  your AquaLink  RS AquaPalm  system  can  be 

changed. The AquaPalm Handheld Remote and the 

AquaPalm Transceiver J-box 

must be set to the same 

RF channel

1.  At the Transceiver J-box, remove the cover 

to expose the PCB (see Figure 6).

2.  On the AquaPalm Handheld Remote, press 

and  hold  both  the  UP  and  DOWN  arrows 

simultaneously for three (3) seconds. After 

3  seconds,  the  CHANNEL  SETUP  screen 

appears (see Figure 7). Select a channel.

3.  Use the UP and DOWN buttons to highlight the 

desired RF channel. Then press SELECT.

4.  When the RF channel is selected, the 

following message appears on the 

AquaPalm display screen: 

Set slide switch on J-Box PCB to the 

LEARN MODE.

5.  At the PCB in the Transceiver J-box, slide the 

Learn Switch to LEARN (ON). See Figure 8.

Figure 5.  Battery Installation on Handheld Remote

UM-3/R6/AA

UM-3/R6/AA

BATTERY

1.5V x 2

3032401

MODEL NO 8265

FCC ID:  S8F826X

Rated:  3V DC

AquaPalm 

Handheld Remote 

(Back View)

Two (2)  

AA Batteries

Battery Chamber

Cover for Battery 

Chamber

Screws

Figure 6.  AquaPalm Transceiver J-Box - Internal 

View

MAIN CONNECTOR

RESET

D2

D3

LE

A

R

N

Y B R

G

O

F

F

O

N

Transceiver 

PCB

Reset Switch

Learn 

Switch

Green 

LED

Red 

LED

SET RF CHANNEL

RF CHANNEL:   1

Use ARROW KEYS
to set the 
RF CHANNEL.
Press SELECT to
continue.

AquaPalm 

1

2

select

back

UP 

Button

DOWN 

Button

SELECT Button

Figure 7.  AquaPalm Handheld Remote Channel 

Setup and Buttons

Summary of Contents for AquaPalm

Page 1: ...hese limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not ins...

Page 2: ......

Page 3: ...h 10 Section 5 AquaPalm Handheld Remote Menus 10 5 1 Pool Mode Spa Mode 10 5 2 Equipment On Off Menu 10 5 3 Filter Pump Pool Mode 11 5 4 Spa 11 5 5 Pool Heat 12 5 6 Spa Heat 12 5 7 Solar Heat 13 5 8 A...

Page 4: ...regnant or possibly pregnant women should limit spa water temperatures to 100 F 38 C c Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since...

Page 5: ...ur health Do not permit any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub The use of alcohol drugs or medication can greatly increase the ris...

Page 6: ...g death serious injury or property damage Turn off power at the main circuit feeding the AquaLink RS Power Center to disconnect the Power Center from the system Section 3 Installation Figure 1 AquaPal...

Page 7: ...least 8 from any air blowers that may be in the vicinity see Figure 4 3 The Transceiver J box antenna must point towards the sky NOTE To improve performance of the transceiver mount the J box more tha...

Page 8: ...appears see Figure 7 Select a channel 3 UsetheUPandDOWNbuttonstohighlightthe desired RF channel Then press SELECT 4 When the RF channel is selected the following message appears on the AquaPalm displa...

Page 9: ...e the AquaPalm Handheld Remote to turn your pool spa equipment on and off in one of the following ways 1 Activate the main equipment on the front screen by highlighting the selection then press SELECT...

Page 10: ...set temperature When SPA MODE is selected the valve actuators rotate to allow flow to the spa pool spa combination systems and the filter pump is turned on If SPA HEAT is enabled the heater will fire...

Page 11: ...14 Equipment On Off Menu Spa EQUIPMENT FILTER PUMP SPA POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3 MORE 2 POOL OFF OFF OFF OFF 1 select back AIR 78 80 POOL MODE POOL HEATER SPAMODE SPAHEATER MENU...

Page 12: ...re The SPA HEAT enables the heater for the spa The desired temperature can be set from the SET TEMP menu or you can increase decrease the temperature when enabling the heater EQUIPMENT FILTER PUMP SPA...

Page 13: ...Sensor not Installed EQUIPMENT FILTER PUMP SPA POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3 MORE 2 POOL ON OFF OFF OFF 1 select back AIR 78 80 POOL MODE POOL HEATER SPAMODE SPAHEATER MENU EQUIPMENT...

Page 14: ...t to a value greater than 0 and the filter pump is on the system salinity level and output percentage appears on the equipment status screen SET TIME 10 10 05 MON 10 00 AM Use ARROW KEYS to set value...

Page 15: ...N MENU SET TEMP SET TIME PALM OPTIONS 1 2 select back BACKLIGHT LIGHT ON LIGHT OFF Choose setting and press SELECT 1 2 select back AquaPalm AquaPalm AquaPalm To change the Auto Shut off Time Highlight...

Page 16: ...FILTER PUMP SPA POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3 MORE 1 2 select back 1 2 select back ASSIGN HOTKEYS 1 AUX1 2 AUX2 Choose setting and press SELECT 1 2 select back ASSIGN HOTKEYS 1 AUX3...

Page 17: ...URE SET OUTPUT BOOST START GO BACK EQUIPMENT ON OFF SELECT EQUIPMENT ON OFF ALL OFF LIGHT ON LIGHT OFF 2 MINUTES 5 MINUTES 10 MINUTES 1 2 ONETOUCH MENU SET TEMP POOL HEAT SPA HEAT CHILL MAINTAIN HOURS...

Page 18: ...correctly the system will not communicate AquaPalm Handheld Remote backlight is on and the startup screen is displayed but override switches at the power center do not operate at all 1 Damaged or imp...

Page 19: ...Page 19 NOTES...

Page 20: ...uthorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals upstream of...

Reviews: