Page 8
4. Re-install the cover for the battery chamber
and secure with the two (2) screws removed
in Step 2.
3.4
Changing the Frequency Channel
If your AquaLink RS AquaPalm system is turning
items on or off at undesignated times, another
AquaLink RS AquaPalm system may be in close
proximity using the same or similar frequency
channel. To prevent unwanted operation the channel
for your AquaLink RS AquaPalm system can be
changed. The AquaPalm Handheld Remote and the
AquaPalm Transceiver J-box
must be set to the same
RF channel
.
1. At the Transceiver J-box, remove the cover
to expose the PCB (see Figure 6).
2. On the AquaPalm Handheld Remote, press
and hold both the UP and DOWN arrows
simultaneously for three (3) seconds. After
3 seconds, the CHANNEL SETUP screen
appears (see Figure 7). Select a channel.
3. Use the UP and DOWN buttons to highlight the
desired RF channel. Then press SELECT.
4. When the RF channel is selected, the
following message appears on the
AquaPalm display screen:
Set slide switch on J-Box PCB to the
LEARN MODE.
5. At the PCB in the Transceiver J-box, slide the
Learn Switch to LEARN (ON). See Figure 8.
Figure 5. Battery Installation on Handheld Remote
UM-3/R6/AA
UM-3/R6/AA
BATTERY
1.5V x 2
3032401
MODEL NO 8265
FCC ID: S8F826X
Rated: 3V DC
AquaPalm
Handheld Remote
(Back View)
Two (2)
AA Batteries
Battery Chamber
Cover for Battery
Chamber
Screws
Figure 6. AquaPalm Transceiver J-Box - Internal
View
MAIN CONNECTOR
RESET
D2
D3
LE
A
R
N
Y B R
G
O
F
F
O
N
Transceiver
PCB
Reset Switch
Learn
Switch
Green
LED
Red
LED
SET RF CHANNEL
RF CHANNEL: 1
Use ARROW KEYS
to set the
RF CHANNEL.
Press SELECT to
continue.
AquaPalm
1
2
select
back
UP
Button
DOWN
Button
SELECT Button
Figure 7. AquaPalm Handheld Remote Channel
Setup and Buttons