6.2 Backwashing

1. With 

the 

fi

 lter pump off, set the backwash valve 

or diverter valve handle to the "BACKWASH" 
position.

Caution

Maintain your pressure gauge in good working order. 
The pressure gauge is the primary indicator of how 
the 

fi

 lter is operating. 

2. 

Open the air release valve.

3. 

Stand clear of the 

fi

 lter and start the pump to 

circulate the water backwards through the 

fi

 lter to 

the waste line. 

4. 

When a steady stream of water is expelled through 
the air release valve, close the valve.

5. 

Run the pump until the backwash discharge water 
is clear (repeat steps 1 thru 5 if required).

6. Switch 

the 

fi

 lter pump 

off

.

7. 

Follow the procedure for coating the 

fi

 lter grids as 

described in Section 4.2.

6.3 Pressure Gauge

1. 

During operation of the 

fi

 ltration system, check 

the pressure gauge/air release assembly for air or 
water leaks at least once a week.

2. 

Keep the pressure gauge in good working order. 
If you suspect a problem with the gauge, Zodiac 
recommends that you call a service technician to 
do any work on the 

fi

 lter/pump system.

6.4  Cleaning the Filter Grids with Water

1. 

Turn off the pump and switch off the circuit 
breaker to the pump motor. Open the air release 
valve on top of the 

fi

 lter tank. Close the 

fi

 lter 

isolation valves. Remove the drain plug.

2. 

Once all pressure has been relieved, 

remove the 

clamp ring and the 

fi

 lter lid. Inspect the o-ring for 

cracks or tears and replace if necessary.

3. Remove 

the 

fi

 lter grid assembly from the 

fi

 lter. 

Follow the instructions in Section 5.1.

4. 

Using a garden hose, thoroughly 

fl

 ush all 

contaminates from the 

fi

 lter grid surfaces.

9. 

Place the tie rod knob on the tie rod and tighten. 
Tighten until the 

fi

 lter grid assembly is snug. 

Do not overtighten.

10.  Reassemble the tank o-ring and tank lid.

11.  Reinstall the tank clamp ring. See Section 3.5 for 

clamp installation.

Section 6. Maintenance

6.1 General Maintenance

1. 

Wash outside of 

fi

 lter with a mild detergent and 

water. Rinse off with a hose. 

Do not use solvents 

to clean the 

fi

 lter. Solvents will damage the 

plastic components of the 

fi

 lter.

 

2. 

Inspect the DE 

fi

 lter grids at least twice a year. 

Remove any foreign material that has not been 
backwashed out of the system.

3. 

Check pressure during operation at least once a 
week.

4. 

Remove any debris from the pumps and pool 
skimmer baskets.

5. 

Check pump and 

fi

 lter for any leaks. If any leaks 

develop, 

turn off the pump and call a pool service 

technician

.

6. 

Product safety signs or labels should be 
periodically inspected and cleaned by the product 
user as necessary to maintain good legibility for 
safe viewing distance.

7. 

Product safety signs or labels should be replaced 
by the product user when a person with normal 
vision, including corrected vision, is no longer 
able to read the safety signs or label message panel 
text at a safe viewing distance from the hazard. 
In cases where the product has an extensive 
expected life or is exposed to extreme conditions, 
the product user should contact either the product 
manufacturer or some other source to determine 
means for obtaining replacement signs or labels.

Caution

Be sure that all provisions for wastewater disposal 
meet local, state or national codes. One hundred 
gallons (100 gals.) or more of pool water will be 
discharged during 

fi

 lter backwashing. Do not 

discharge water where it will cause 

fl

 ooding or 

damage.

8. 

Installation of new replacement safety signs or 
labels should be in accordance with the sign or 
label manufacturer's recommended procedure.

Summary of Contents for DEV Series

Page 1: ...ficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly Before install ing this product read and follow all warning not...

Page 2: ...bing 6 3 5 Clamp Installation DEV Series 7 Section 4 Start Up and Operation 8 4 1 Preparing Diatomaceous Earth 8 4 2 Coating the Filter Grids 9 4 3 New Pool and Seasonal Start up 9 4 4 Valve Operation...

Page 3: ...etc is serviced air can enter the system and become pressurized when the system is restarted Pressurized air can cause product failure or also cause the filter lid to be blown off which can result in...

Page 4: ...ion system should be designed to meet local health codes At a minimum the system should turnover the total volume of water in your pool two to four times in a 24 hour period 2 3 General Requirements 1...

Page 5: ...tion and return lines to prevent back flow of pool water during any routine servicing that may be required 3 2 Anchor Bracket Installation In Florida building codes require that all appliances be secu...

Page 6: ...nk located in the accessory bag 3 4 Filter Plumbing Figure 4 Basic Pool Spa Combination Plumbing Anchor Bracket Qty 4 12x1 Pan Head Screw Qty 8 Tank Bottom Filter Tank Anchor Bracket Installation Anch...

Page 7: ...pes using the unions supplied with the filter Do not use teflon tape or pipe dope on any unions Assemble the unions dry and hand tighten CAUTION Be sure that all provisions for wastewater disposal mee...

Page 8: ...s without use of diatomaceous earth DE DE is the substance that filters the water the filter cloth merely supports the DE Operating without DE will damage filter grids and shorten filtering cycles Cau...

Page 9: ...e system and make sure that the filter drain plug is in place 5 Stand clear of the filter and start the pump to circulate water through the system When a steady stream of water starts to come out of t...

Page 10: ...ion Function FILTER Normal filtration and vacuuming BACKWASH Cleaning filter by reversing the flow RINSE Used after backwash to flush dirt from the valve WASTE Bypasses filter used for vacuuming waste...

Page 11: ...rod knob on the tie rod and tighten Tighten until the filter grid assembly is snug Do not overtighten 10 Reassemble the tank o ring and tank lid 11 Reinstall the tank clamp ring See Section 3 5 for cl...

Page 12: ...otection when mixing the solution and handling or rinsing the filter grids 4 Soak for at least four 4 hours 5 Rinse the filter grids thoroughly with water 6 See Sections 5 1 and 5 2 for reassembly of...

Page 13: ...p Check all lines for debris or partially closed valves Clean or replace filter grids per instructions Fill pool so level is above pump inlet line Fill pump with water at basket and replace lid Techni...

Page 14: ...d Full Size DEV60 7 required R0359100 DE Grid Full Size DEV48 7 required R0555000 19 DE Grid Short Span DEV60 1 only R0359200 DE Grid Short Span DEV48 1 only R0554900 20 Tie Rod Knob R0359400 21 Ring...

Page 15: ...DEV Series Filter Section 10 Head Loss Curves 10 1 Jandy DEV Filter Design Head Loss Curves 0 2 4 6 8 10 12 14 16 18 20 22 0 30 60 90 120 150 0 1 2 3 4 5 6 7 8 9 DEV48 DEV60 Design Head Loss ft head...

Page 16: ...ZODIAC POOL SYSTEMS INC 6000 Condor Drive Moorpark CA USA 93021 800 822 7933 Fax 877 327 1403 2010 Zodiac Pool Systems Inc All rights reserved 1006 H0295200 Rev B...

Reviews: