Problem

Possible Cause

Corrective Action

Lights don’t turn on

Lights are not 

powered

Check the 120VAC power 

supply into the transformer, 

14VAC output at the 

transformer, and ensure 

the lights are enabled via 

the iAquaLink app. Check 

or reset the GFCI. Make 

sure 120 volts has not been 

used in the installation. If so, 

damage is assured and is 

not warrantable.

One or more lights are 

dim, blinking or not 

working

Poor connection or 

improper wire gauge

Separate each light and 

independently wire 14VAC 

to a single light only. Repeat 

this process for each light. 

If the junction box is being 

used, then check for proper 

connection of the light 

cord. Verify that the correct 

wire gauge is being used 

between the transformer and 

junction box.

Lights are flashing 

 

yellow

Lights are not  

communicating with 

the Infinite 

 

WaterColors LED 

Light Controller or 

lights are connected 

to a non-compatible 

controller or 

 transformer.

Confirm lights are powered 

by the Infinite WaterColors 

LED Light Controller. If 

not, then connect and try 

again. If they’re powered, 

then check the RS-485 

connection.

Different colors from 

 

different lights

Zones are set 

differently

Check that lights are in the 

same zone, or that all zones 

are set to the same color.

ETL LISTED

CONFORMS TO

UL STD 676

CERTIFIED TO

CAN/CSA C22.2 NO.89

Summary of Contents for Infinite WaterColors IWC15W100

Page 1: ...d and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper install...

Page 2: ...ng the Light Fixture 8 3 3 Wet Area Installations 9 Section 4 Controller Wiring Options 10 4 1 Wiring to an AquaLink RS Control System 10 4 2 Wire Gauge and Length 11 4 3 Fourteen 14 Volt Installation...

Page 3: ...ned to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in ac...

Page 4: ...or property damage Visit www zodiacpoolsystems com for additional free copies of these instructions or call Zodiac Technical Support at 800 822 7933 U S or 888 647 4004 Canada DANGER RISK OF ELECTRICA...

Page 5: ...order to prevent risk of property damage and or injury no service should be attempted to the light in the event of a malfunction The complete light assembly must be replaced WARNING RISK OF ELECTRICA...

Page 6: ...st be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code Canadian Electrical Code in Canada and all applicable local codes...

Page 7: ...roller is suitable for direct conduit connection to lights and must be located at least 8 inches above water level at least four 4 inches above ground level and at least 48 inches 4 feet from the edge...

Page 8: ...m possible water line top of copping Figure 1 Jandy LED Light Installation with Standard 1 5 Plastic Fitting Use the chart below to determine the appropriate pipe length for your installation WATTS MI...

Page 9: ...are too small for use with the Jandy Infinite WaterColors Nicheless LED Lights 6 Using the included installation tool thread the light into the wall fitting until it is snug The light face must be co...

Page 10: ...transformer The maximum run of service between transformer and lights should not exceed 200ft in length inclusive of the use of a J Box or not To the extent allowed by local installation codes in effe...

Page 11: ...hts to the LED Light Controller Refer to the Infinite WaterColors LED Light Controller manual for connecting to the AquaLink RS automation system 1 Knock out an opening in the right compartment 2 Run...

Page 12: ...Jandy Lights to any dimming circuitry DO NOT CONNECT TWO OR MORE POWER SUPPLIES IN PARALLEL CAUTION To prevent risk of fire which could result in property damage and to ensure optimum performance do n...

Page 13: ...e and follow further instructions in the app NOTE When exiting the Light Zone Setup page the lights will turn off NOTE Lights have to be assigned to a zone in order to rename the zone 5 1 2 Name Light...

Page 14: ...ction 6 OneTouch Setup 6 1 Light Setup 6 1 1 Assign Lights 1 Choose menu on the OneTouch display screen and press select 2 From the menu screen go to System Setup IWC Lights 3 Select zone set up 4 Fro...

Page 15: ...4 or more above or below the light depending on the pool s other winterization needs Consult a Local Swimming Pool Professional for proper winterization At NO TIME should there be water removed from...

Page 16: ...warrantable One or more lights are dim blinking or not working Poor connection or improper wire gauge Separate each light and independently wire 14VAC to a single light only Repeat this process for e...

Reviews: