Correctly sizing the blower for your application is a critical step to the sustained operational quality 

of your Jandy Pro Series Pool and Spa Blower. Damage or failure due to an improperly sized 

blower is not covered under warranty.

SIZING WORKSHEETS:

  The worksheets below will guide you through the proper sizing 

calculations for your application.

1. SELECT BLOWER

2. PLUMBING

3. WIRING

Vertical Measure from Pool/Spa surface to air outlet

Number of feet of 2” Pipe
Number of 90° Elbows
Number of 45° Elbows
Number of 1/2 lb check valves

Total Back Pressure

(Inches of Water)

Calculate Back Pressure

4

a

b

c

d

e

Vertical Measure from air outlet to lowest check valve 

(See Note)

a

1

10
.5
.125

Calculate back 

pressure as a measure 

of “inches of water”. 

Verifi cation of this 

fi gure can be made by 

using a manometer.

AIR HOLE

SIZE

CONVERSION

FACTOR

Calculate Airflow

1

8

5

32

3

16

1

4
3

8

1.2

0.15

0.1

0.27

0.6

1.1

1.5

2.4

Jet

Total Airflow

SCFM

(Standard Cubic Feet Per Minute)

Conversion

Factor

No. of Holes

Air Flow Rate (SCFM)

Pressure H

2

O (Inches of W

ater)

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140

10

0

20

30

40

50

60

70

80

90

100

110

120

130

Performance Curves (60 HZ)

Models: PSB110

Models: PSB115

Models: PSB120

Max Back Pressure 

40"

Max Back Pressure 

50"

Max Back Pressure 

65"

Models: PSB210

Models: PSB215

Models: PSB220

Voltage

Blower Selection

120V

1.5 HP

2.0 HP

1.0 HP

PSB110

PSB115

PSB120

240V

PSB210

PSB215

PSB220

Determine Blower Needed

Choose an air hole size from 

the chart at left and apply the 

conversion factor in the formula 

below to determine total airfl ow in 

standard cubic feet per minute.

Installation of this equipment should be performed by a 

licensed electrician and conform to all National Electrical Code

®

 

(NEC

®

), state and local codes.

1.  Ensure all power to the blower has been 

disconnected at the main breaker.
2.  Remove blower front door by removing 

the two (2) screws sliding the door 

downward and pulling the door free.
3.  Pull in voltage source and ground 

wire from Power Center.
4.  Connect wires from power center to 

the corresponding wires from the blower 

motor. Use the wiring diagrams below for 

reference. The 120 or 240 toggle switch 

will come preinstalled with fl ag terminals. 

Connections will need to be made with 

Wire nuts.

 WARNING

Installing an insuffi ciently 

sized blower will 

increase back pressure. 

Failure to accurately 

follow the blower 

sizing calculations 

provided could result 

in excessive back 

pressure. Excessive 

pressure can cause 

damage that could result 

in electrocution causing 

severe injury or death.

Water Line

Water Line

Air Line

Check V

alve*

Spa Return

To Pump

Sump

to wa

ter le

vel

12” min.

5’   -   25’

min.

max.

Bubbler Jet

Venturi Jet

Blower

(installation with

Venturi Jets 

)

Blower

(installation with

Bubbler Jets)

* Install a 1/2 lb. U.L. listed check valve between the 

blower and the jets to prevent water damage to the blower. 

Ensure that check valves are accessible for servicing.

 Do not install adjustable jets. These may cause 

excessive back pressure.

ON

OFF

Line 1

Neutral Bus Bar

Ground Bus Bar

From Blower Motor

From Power Center

Power Center

120V Toggle Switch

Flex Conduit

120V Wiring

RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS 

INJURY OR DEATH. Before attempting installation, ensure that all 

power to the device is disconnected/turned off at the circuit breaker. 

Be careful not to damage or abrade any wiring or other components.  

LEGEND

Line 1
Neutral
Ground

ON

OFF

Line 2

ON

OFF

Line 1

Ground Bus Bar

From Power Center

Power Center

Flex Conduit

From Blower Motor

240V Toggle Switch

LEGEND

Line 1
Line 2
Ground

240V Wiring

RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS 

INJURY OR DEATH. Before attempting installation, ensure that all 

power to the device is disconnected/turned off at the circuit breaker. 

Be careful not to damage or abrade any wiring or other components.  

Water Line

Water Line

Air Line

Air Line

Check V

alve*

Sump

Spa Return

To Pump

to wa

ter le

vel

12” min.

Over 25 F

eet

Hartf

ord loop

Plum

b as 

close t

o the 

pool/

spa w

all 

as po

ssible

.

Bubbler Jet

Venturi Jet

* Install a 1/2 lb. U.L. listed check valve between the blower 

and the jets to prevent water damage to the blower. 

Ensure that check valves are accessible for servicing.

 Do not install adjustable jets. These may cause excessive 

back pressure.

Blower

(installation with

Venturi Jets 

)

Blower

(installation with

Bubbler Jets)

LONG RUN INSTALLATION

(over 25’ from spa wall)

STANDARD INSTALLATION

Screw

Conduit

Wires

Blower Door

Blower

From

Power Center

2” min.

water

level

Check

Valve*

Sump

Bubbler Jet

Blower

Water Line

Air Line

Spa

Return

To

Pump

Water Jet

* Install a 1/2 lb. U.L. listed check valve between the 

blower and the jets to prevent water damage to the blower. 

Ensure that check valves are accessible for servicing.

Hartford Loop -

 

To install the 

blower below 

water level, or if 

the blower air 

line drops 

below the 

bottom of the 

spa, use the 

Hartford Loop 

plumbing 

configuration to 

prevent the air 

line from filling 

with water.

BELOW GRADE INSTALLATION

a

a

1

Spa

Deck

Grade

Blower

e

d

b

c

NOTE: 

Include a

for  

installations with a check 

valve below the air outlet 

only. See “Below Grade 

Installation” on facing page 

for details. For above grade 

installations enter 0 for a

1

.

Locate the total back pressure, calculated above 

and draw a horizontal line. Locate the total airfl ow 

from previous step and draw a vertical line. These 

lines will intersect on the performance curve of the 

minimum HP blower required for your application.