Model LJ Pool and Spa Heater
Page 23
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion
may result, causing property damage, personal injury or loss of life.
OPERATING INSTRUCTIONS
9. Replace control access panel
10. Turn on all electric power to appliance.
11. Set thermostat to desired settings for "Pool"
and "Spa" and change the controller mode
from "OFF" to either "POOL" or "SPA".
12. If the appliance will not operate, check that
the filter pump is on, the filter is clean and
water is flowing to the pool. Otherwise,
follow the instructions "To Turn Off Gas To
Appliance" and call your service technician
or gas supplier.
A. This appliance does not have a pilot light.
It is equipped with an ignition device
which automatically lights the heater. Do
NOT try to light the burners by hand.
B. BEFORE OPERATING, smell all around the
appliance area for gas. Be sure to smell
next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance
Do not touch any electric switch; do not
use any phone in your building.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand,
don't try to repair it, call a qualified
service technician. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect
the appliance and to replace any part of
the control system and any gas control
which has been under water.
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat for "Pool" and "Spa" to
70°F(21°C) and the controller mode to "OFF"
2. Turn off all electric power to the appliance
if service is to be performed.
3. Turn gas control knob clockwise
to
"OFF".
4. Replace control access panel.
DIRECTION OF
GAS FLOW
1. STOP! Read the safety information above on
this label.
2. Set the thermostat for "Pool" and "Spa" to
70° F (21°C)and the controller mode to
"OFF".
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition
device which automatically lights the heater.
Do not try to light the burners by hand.
5. Remove the heater door.
6. Turn gas control knob clockwise
to
"OFF".
7. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the
safety information above on this label. If you
don't smell gas, go to next step.
8. Turn gas control knob counterclockwise
to "ON".
Summary of Contents for LJ
Page 45: ...Model LJ Pool and Spa Heater Page 43 NOTES...
Page 46: ...Page 44 NOTES...