Page 19
CAUTION
Do not overtighten the strain relief fitting. Overtightening can cause damage to the Flow/Temp/Salinity
Sensor cable or DC cord.
10. Plug the DC cord into the Cell stud terminals protruding from the Cell top (see Figure 13). The DC
cord can be plugged into the cell in either direction.
11. Connect the DC cord to the Power center. Feed the DC cord through the same strain relief fitting as
the Flow/Temp/Salinity Sensor. Plug the DC cord into the two spade connectors of the wiring harness
located in the low voltage raceway of the power center, see Figure 2. This wiring harness establishes
the connection between the Cell and the Printed Circuit Board mounted on the back plate.
12. Tighten strain relief fitting screws for the
Flow/Temp/Salinity Sensor and the DC cord.
Do not pull
Flow/Temp/Salinity Sensor cable or DC Cord too tight. Allow a little slack cable inside of Power
center Enclosure.
13. Prior to reattaching front cover, check the wiring. Be sure the Flow/Temp/Salinity Sensor is plugged
in. The DC cord should be plugged in. Also, check the AC wiring.
14. Plug the ribbon cable attached to the front cover PC board into Printed Circuit Board mounted on the
backplate (see Figure 2). Now reattach the power center front cover to the backplate.
3.6 Connection to the AquaLink
®
RS PureLink Control System
The Jandy AquaLink RS PureLink is a multi-function pool controller and can fully control the function of
the AquaPure chlorine generator. The AquaPure will display JA when a button is pressed at the AquaPure
while the Jandy AquaLink RS PureLink is in control. Adjustment of the AquaPure chlorine production rate
can be controlled from the main menu of the AquaLink RS Controller (All Button, OneTouch, or PDA).
Boost mode may be activated from the AquaPure while the AquaLink RS is online. Refer to the
AquaLink RS Operation Manual
(or
AquaLink RS PDA Operation Manual
) for more information. The
AquaPure temperature, salinity, service codes, and LED indicators operate as normal.
NOTE
The AquaPure Chlorine Generator will communicate with AquaLink RS using firmware versions JJ or later.
Referring to Figures 2a or 2b, wire the PureLink Power Center transformer to the load side of the filter
pump relay.
NOTE
The screw terminals are removable to aid in installation.