background image

Janfire

pelletswärme

swedish quality

There will be no compensation for any costs of replacement. 

!

Warranty  will  be  lost  if  the  product  is  not  installed,  set  into  operation, 

maintained and handled properly. 

!

Janfire  will  not  give  any  warranty  for  faults  concerning  the  hydraulic,  the 

electric installation or the flue gas system. 
The boiler may not be used without adequate water pressure or without being 

connected to the hydraulic - and the flue gas system.

Warranty  will  be  lost  by  the  use  of  not  permitted  fuel,  insufficient  draft,  insufficient  handling, 

maintenance and no proper installation. 

Warranty will be lost too, if changes or repairs are made without our permission.

There will be no responsibility for damages evoked by leakage water, corrosion, aggressive vapours, 

dust, humidity (for example laundry dryer or washer in the boiler room), overpressure, assembly of 

the boiler in areas with explosive atmosphere or damages evoked by oxygen or dirt in the hydraulic 

system. 

Advanced claims are excluded, especially any claim for damages, if they are not founded by law.

If a warranty claim was not justified, we will bring our costs to account.

3     

Brief description / scope of delivery / allowed fuels

The usage of the Janfire Combiflame guaranties an environmentally friendly and economic operation 

during heating. By the use of renewable fuels like wood pellets or log the heating is CO2-neutral. 

Only the same amount of CO2 will be released to the atmosphere that the tree has collected during 

its growth. 

Advantages:

• good value combi boiler for heating and domestic hot water supply

• simple design and high performance

• can be used as an additional boiler to existing oil- or gas heating systems

• good isolation, causes only few thermal lost

• nominal heat output for pellets 20 kW 

• only 15 Pa natural draft is needed

• easy to change from pellets into a log boiler and reverse

• easy to clean and maintain

The Combiflame is a steel boiler conform with EN 303-5. The combustion chamber consists of 5 

mm sheets from ST35JR (EN10025). The outside of the pressure vessel consists of 3 mm. 100 mm 

Summary of Contents for Combiflame

Page 1: ...Janfire pelletsw rme swedish quality Janfire Combiflame Boiler for wood pellets log and brown coal manual...

Page 2: ...lever on the right side of the boiler After the opening of the flap you have to wait a couple of seconds before you may open the front door 2 Warranty terms The warranty will only be issued on faults...

Page 3: ...n or dirt in the hydraulic system Advanced claims are excluded especially any claim for damages if they are not founded by law If a warranty claim was not justified we will bring our costs to account...

Page 4: ...d this manual Purchased parts package Boiler Combiflame including the catalytic converter four adjustable feet ash pit grill for operation with log pellet burner NH thermal controller for the draft fl...

Page 5: ...23 24 25 26 27 28 connector female screw thread for thermal relief valve flue gas connector muffle 1 for backflow pellet burner thermostat safety relief switch main switch therm relif heat exchanger...

Page 6: ...rn temperature C 55 flue gas average temperature mass flow cross section of flue gas connector average CO2 level in flue gas at nominal heat output average CO level 13 O2 at nominal heat output C g s...

Page 7: ...ief heat exchanger The Combiflame has a welded thermal safety relief heat exchanger The thermal safety relief heat exchanger may not be used as a domestic hot water supply This heat exchanger has to b...

Page 8: ...the maximal operation time adjustable in burner menu a fault message will appear in the display of the burner This case normally happens at the first start running or if you run out of pellets The in...

Page 9: ...ong to the state of the art and work Ask local authorities before installation The heating room has to be conform to the local fire protection requirements If a ventilating system is installed make su...

Page 10: ...r falls below the triggered temperature the burner will start again This kind of regulation is very inefficient and uncomfortable 8 2 2 Modulating operation The burner can be equipped with a modulatio...

Page 11: ...em can be fount in chapter 4 No part of the flue gas system is allowed to be more tighten than the flue gas connector of the boiler A draft regulator is required This regulator is not part of the purc...

Page 12: ...ic cold water supply But it is allowed to operate the boiler with pellets in this case The Combiflame is equipped with a built in thermal safety relief switch conform with EN 303 5 clause 3 21 In case...

Page 13: ...ust them again if necessary 5 Connect the plugs of the burner according to the electric plan The electric connection has to be made according to the local terms by an expert The hose between the auger...

Page 14: ...he connection between burner and auger system and the modulation sensor Open the screw hooks and remove the burner 6 Make sure that the burner and the hose will be stored properly The draft flap has t...

Page 15: ...Start and adjust the burner as said in the manual Make sure that the ash pit is empty and the main heat exchanger and the catalytic converter are clean Do not open any door of the boiler during operat...

Page 16: ...m thick bed of glow Than put the briquette on top of the glow There should be a distance from about 5 cm between the briquettes 3 The front grill has to be covered by the delivered cover sheet start u...

Page 17: ...the front door until you have opened the start up flap by pulling the lever on the right side of the boiler After the opening of the flap you have to wait a couple of seconds before you may open the f...

Page 18: ...an the main heat exchanger an the flue gas system every month cleaning of the grill Never use a vacuum cleaner to clean the grill There is a high risk of fire because of remaining glow Open the bottom...

Page 19: ...mney too 17 Advice to averting of a danger To reduce risk you have to follow all instructions of this manual everytime you use this boiler autumn and spring The natural draft of the chimney depends on...

Page 20: ...door of the boiler has to be kept close Wear fire proved glows any time you open a door during heating Do not open the front door until you have opened the start up flap by pulling the lever on the ri...

Page 21: ...Janfire pelletsw rme swedish quality...