Installation Instructions Janfire Pellet Boiler Integral Typ 25
IA 32580002 EN_Ver5
Janfire 2014
14(25
)
4.3 Boiler
The Janfire pellet boiler can be supplied ready-assembled with a shunt as option. The boiler has a large
water volume (180 litres) and does not need to be connected to a storage tank.
In
other
cases
where the
storage tank
shall
be used,
connect
it with
the connections
on the backside.
Plug and socket for connecting to power, circulation pump and burner are supplied.
The soot sweeping mechanism is mounted under the cladding on the left side.
Installation example with heat exchanger in Boiler
A
Thermostat mixer
H
Cirkulation pump
B
Domestic Hot water supply
J
Valve
C
Inlet cold water
K
Mixing valve
D
Expansion vessel
L
Return radiator
E
Radiator
M
Supply radiator
F
Adjustment valve
N
Drain valve
G
Non-Return valve