24
ProData II
S0 pulse input
You can connect an S0 pulse transducer per
DIN EN62053-31 to any digital input.
This requires an auxiliary voltage with an output voltage in
the range 20 .. 27 V DC and a resistor of 1.3 kOhm/1 W.
S0 plug-in module
(optional, article number 52.24.111)
• Enables simple and fast connection of S0 pulse
transducers.
• Module for a group of 5 inputs with integrated
resistors.
6
5
4k
Digital
Input 5
4
4k
Digital
Input 4
3
4k
Digital
Input 3
2
4k
Digital
Input 2
1
4k
Digital
Input 1
3,9V
3,9V
3,9V
3,9V
3,9V
ProData 2
Digital inputs 1-5
-
+
24 V DC
External
Auxiliary voltage
S0
pulse
trans-
ducer
1.3 k/1 W
Fig.: S0 plug-in module
to connect
S0 pulse transducers