48
ProData II
Technical data
General information
Net weight (with attached connectors)
approx. 200 g
Packaging weight (including accessories)
approx. 440 g
Battery
Lithium battery CR2032, 3V (approval i.a.w. UL 1642)
Transport and storage
The following information applies to devices which are transported or stored in the original packaging.
Free fall
1 m
Temperature
K55 (-40 °C to +70 °C)
Relative humidity
0 to 90 % RH
Ambient conditions during operation
The ProData 2 is intended for weather-protected, stationary use.
Protection class II in acc. with IEC 60536 (VDE 0106, Part 1).
Flammability rating of housing
UL 94V-0
Working temperature range
K55 (-40 °C to +70 °C)
Relative humidity
5 to 95 % RH (at +25 °C without condensation)
Operating altitude
0 .. 2000 m above sea level
Degree of pollution
2
Mounting / assembly
Mounting rails 35 mm
(in acc. with IEC/EN60999-1, DIN EN 50022)
Mounting position
any
Ventilation
Forced ventilation is not required.
Protection against ingress of solid foreign bodies and water
IP20 in acc. with EN60529