45
To replace the switching power supply unit
To remove:
1. Remove the belt cover, power supply cover and front
cover. (Refer to pages 2 to 4)
2. Disconnect the switching power supply connector
(motor) (white 5P), switching power supply connector
(control) (white 4P) and ErP switch connector (green
2P) from the printed circuit board A.
3. Remove the setscrews A (4 pcs.), setscrew B (2 pcs.)
and remove the switching power supply.
To attach:
1. Follow the steps of removal procedure in reverse.
Switching power
supply unit
Switching power
supply unit
Setscrew A
Setscrew A
Setscrew A
Setscrew B
ErP switch
connector
(Green 2P)
Setscrew A
Switching
power
supply
connector
(control)
(White 4P)
Switching
power
supply
connector
(motor)
(White 5P)