MECHANICAL ADJUSTMENT
PRESSER BAR HEIGHT AND ALIGNMENT
TO CHECK:
1.
Raise the presser foot lever (B).
2.
The distance between the zigzag foot (A) and the needle plate (C) should be 6.0
mm.
If this is not the case, adjust as follows.
ADJUSTMENT PROCEDURE:
1.
Open the face cover.
2.
Raise the presser foot lever (B) and loosen the hexagonal socket screw (D) on the
presser bar bracket (E).
3.
Adjust the distance between the zigzag foot (A) and the needle plate (C) to 6.0
mm.
4.
Tighten the hexagonal socket screw (D) firmly.
Note: When you tighten the hexagonal socket screw (D), make sure the edge of
the zigzag foot (A) is paralleled (G) with the edge of the feed dog (F).