23
TO ADJUST THE CLEARANCE BETWEEN
THE NEEDLE AND THE UPPER LOOPER
Correct setting:
When the upper looper meets with needle, the clearance should be:
0 to + 0.1 mm at the needle on the left.
-0.05 to + 0.05 mm at the needle on the right.
To adjust:
1. Remove the spreader setscrew A and the spreader holding plate .
2. Turn the handwheel toward you with your hand to bring the needle just behind the upper looper in downward
travel.
3. Loosen the setscrew B and adjust the clearance between the both needles and upper looper.
4. Tighten the setscrew B.
5. Check the clearance between the loopers.
6. Set the spreader holding plate and tighten the spreader setscrew A.
Upper looper
Needle
Clearance
Figure 1
Spreader
setscrew A
Figure 2
Spreader
holding plate
Setscrew B
Upper looper drive shaft
Upper looper