2
Face plate (unit)
To remove:
(1) Remove the two set screws (A), and detach the face plate (unit).
To attach:
(2) Temporarily tighten the two set screws (A) to set the face plate (unit).
(3) Close the face plate, level it with the arm, thread tension dial (unit) and top cover, and then
completely tighten the two set screws (A).
Top cover (unit)
To remove:
(1) Loosen and remove the two set screws (B) and (C).
(2) Raise the carrying handle, lift the top cover (unit), and separate the carrying handle stays
from each pin by pushing them from both sides.
(3) Detach the top cover (unit) together with the carrying handle.
To attach:
(4) Put the top cover (unit) and carrying handle together, and fit the carrying handle stays to
each pin while pushing them from both sides.
(5) Attach the top cover (unit) with the two set screws (B) and (C).
(There should no interference with the pressure dial and the clearance between the front
panel and top cover should be uniform.)
Summary of Contents for HD3000