MECHANICAL ADJUSTMENT
NEEDLE BAR HEIGHT
CORRECT SETTING
THE STANDARD DISTANCE BETWEEN THE UPPER EDGE OF NEEDLE EYE AND THE TIP OF
SHUTTLE HOOK SHOULD BE IN THE RANGE OF 2.9 mm - 3.5 mm WHEN THE TIP OF SHUTTLE
HOOK MEETS THE LEFT SIDE OF THE NEEDLE IN ASCENDING TRAVEL OF NEEDLE FROM ITS
LEFT AND LOWEST POSITION.
TO ADJUST
1.
REMOVE THE FACE PLATE. (SEE PAGE 4.)
2.
SET THE PATTERN SELECTOR DIAL AT “B”. (STITCH LENGTH DIAL AT ANY POSITION.)
NOTE:
FOR MODEL JF1004 , SET THE PATTERN SELECTOR DIAL AT “ “.
FOR MODEL JF1022 AD JF1018, SET THE PATTERN SELECTOR DIAL AT “A”.
SET THE WIDTH SELECTOR DIAL AT “ 0 “.
3.
REMOVE THE SHUTTLE RACE RING.
4.
TURN THE BALANCE WHEEL TOWARD YOU UNTIL TIP OF SHUTLE HOOK MEETS THE
LEFT SIDE OF THE NEEDLE.
5.
LOOSEN THE NEEDLE BAR CONNECTING STUD SET SCREW.
6.
ADJUST THE HEIGHT OF THE NEEDLE BAR BY REMOVEING THE NEEDLE BAR UPWARD
OR DOWNWORD WITHOUT TURNING IT.
7.
TIGHTEN THE SET SCREW.
8.
ATTACH THE SHUTTLE RACE RING.
9.
ATTACH THE FACE PLATE.
NEEDLE BAR CONNECTING
STUD SET SCREW
NEEDLE BAR
TIP OF SHUTTLE HOOK MEETS LEFT
SIDE OF NEEDLE.
2.9 mm - 3.5 mm
15