9
• The distance between the bottom of the presser foot in up position and the needle plate should
be 6.0 mm.
<To adjust>
Remove the face plate and needle.
Lower the feed dog below the needle plate. Place a block 6 mm thick under the presser foot and
lower the presser foot lifter.
Loosen the setscrew (A). Raise the presser foot lifter and tighten the setscrew (A) firmly.
Attach the needle and face plate.
Attach the face plate.
NOTE:
Make sure that the presser foot should be parallel to the feed dog slots (B) in the needle plate.
Setscrew (A)
6mm
Presser foot height
Presser foot
Needle plate
Feed dog
Presser foot alignment
Presser foot should
be parallel to the
feed dog slots.
Adjusting Presser Foot Height and Alignment
Block
(B)
Summary of Contents for Jubilee 60507
Page 1: ...SERVICE MANUAL PARTS LIST MODEL Jubilee 60507...
Page 23: ...PARTS LIST MODEL Jubilee 60507...
Page 24: ...PARTS LIST 22 MODEL Jubilee 60507 1 2 4 4 4 3 13 14 15 5 6 4 4 7 8 9 10 11 6 12...
Page 32: ...PARTS LIST 30 MODEL Jubilee 60507 14 11 10 6 7 9 8 5 5 1 3 15 18 12 16 13 11 17 4 2...
Page 38: ...PARTS LIST 36 MODEL Jubilee 60507 7 8 5 9 12 1 2 3 4 6 6 5 10 13 11 11...
Page 40: ...PARTS LIST 38 MODEL Jubilee 60507 1 2 3 4 5 14 7 11 8 9 10 13 12 6 5 16 15 17 18...
Page 42: ...PARTS LIST 40 MODEL Jubilee 60507 2 3 4 5 6 8 9 11 10 12 1 13 14 15 7...