19
STRETCH STITCH FEED BALANCE
When a stretch stitch pattern is sewn with the feed balancing dial position set at the standard setting mark " ", the
stitch pattern should look like the one marked with a " " (A=B) in the diagram below.
If forward and backward feeding is unbalanced (A>B or A<B), adjust as follows.
ADJUSTMENT PROCEDURE:
1. Turn the power switch on and select the stitch pattern " ".
2. Set the slit of the feed balancing dial to the standard setting mark " " on the front cover.
3. Put a piece of paper under the presser foot and lower it.
Turning the handwheel toward you, and check the needle mark at "A" and "B".
4. Remove the setscrew (A) and base cover.
5. If A>B, turn the adjusting screw counterclockwise "C".
6. When A<B, turn the adjusting screw clockwise "D".
7. Attach the cap.
MECHANICAL ADJUSTMENT
G
F
Adjusting screw
Base cover
Feed balancing dial
Indication line
Standard setting
mark
Setscrew (A)