MC 11000
1. Start the machine in Adjust Mode. Turn the power
switch on while pressing the Start/Stop button and
the reverse button at the same time. (Keep pressing
both buttons until LCD screen shows adjusting
window.)
2. Press the Solenoid key on the touch panel.
3. Remove the bed cover, base and thread cutter cover.
4. Lower the needle bar to its lowest position.
5. When lowering actuator arm (1), “L” will be indicated
on the Solenoid 2 window of the touch panel.
If the screen dose not show “L”, loosen screw (A) and
adjust it by moving the switch left or right.
6. When raising actuator arm (1), “H” will be indicated on
the Solenoid 2 window of the touch panel.
If the screen does not show “H”, loosen the screw (A)
and adjust it by moving the switch left or right.
7. Attach the thread cutter cover, bed cover and base.
(A)
Main
Slave
DC1
Solenoid
X
Solenoid 2
Solenoid 3
Solenoid 1
H
H
84
Adjusting Thread Cutter Switch
(1)
SEWING
THREAD CUTTING
“H”
“L”
38
www.promelectroavtomat.ru