15
MC 9900
,
The embroidery unit carriage position is initialized.
The range between A and B should be in the range
of 7.8 mm to 8.2 mm.
If the range between A and B is smaller than 7.8
mm, loosen the setscrew
r
and move the X-sensor
position to the left.
If the range between A and B is larger than 8.2 mm,
loosen the setscrew
r
and move the X-sensor
position to the right.
Initialize the embroidery unit again and be sure the
range between A and B is in the range of 7.8 mm to 8.2
mm. If not, repeat the procedure and adjust the range
again.
n
Attach the X-sensor.
Tighten the setscrew
r
temporarily.
m
Attach the embroidery unit to the MC9900.
Insert the machine plug into the power inlet.
Insert the power supply plug into the wall outlet and
turn the power switch on.
8±0.2 mm
A
B
y
t
t
y
.
Tighten the setscrew
r
firmly.
⁄0
The shielding plate
t
should be positioned at the
middle of the sensor
y
as illustrated.
If not, loosen the setscrew
u
and adjust the sensor
height.
Tighten the setscrew
u
after the adjustment.
r
u