8
MC200E
Adjusting the Clearance between Needle and Hook
1. Remove the needle plate, bottom plate and bed
cover.
2. Remove the presser foot and bobbin holder.
Replace the needle (#11) with the test pin.
3. Loosen the setscrews (A), (B) and (C) and tighten
the setscrew (C) slightly.
4. Turn the hand wheel to bring the tip of the rotary
hook behind the test pin.
Adjust the clearance between the test pin and the
tip of the rotary hook to -0.0 to +0.05 mm by
moving the rotary hook set plate up or down.
5. Tighten the setscrews (A), (B) and (C) firmly.
6. Check the backlash between the rotary hook gear
and lower shaft gear and adjust the backlash if
necessary.
7. Attach the bobbin holder and presser foot.
Replace the test pin with the #11 needle.
8. Attach the bed cover, bottom plate and needle
plate.
The clearance between the needle and the rotary hook should be -0.10 to +0.05 mm.
Setscrew (A)
Setscrew (B)
Setscrew (C)
Rotary hook
set plate
Test pin
Tip of rotary hook
-0.10 to +0.05 mm