SET
Brightness
SEW TEST
Bobbin
Foot UD
Test
Clear EEPROM
8 Adjust
BH Sensor
Foot Sensor
Main
Ver.
Ver.
Slave
Bobbin Thread
OK
Key
MEM2
MEM1
Adjusting Remaining Bobbin Thread Sensor
To adjust bobbin thread sensor:
1. Start up the machine in Adjusting Mode. Turn
the Power ON while pressing the Start/Stop
button and Reverse button at the same time.
(Keep pressing both buttons until the LCD
shows Adjusting window.)
2. Press the Bobbin key on the touch panel.
3. Insert the gauge bobbin (9.2 mm in diameter)
in the bobbin holder and press the key button.
(The numbers will appear under the key
button. Press the key button several times and
check if the same number appears each time.)
4. Press MEM1 button. (The data for step 3 is
registered in MEM1.)
5. Insert the gauge bobbin (10.3 mm in diameter)
in the bobbin holder and press the key button.
(The numbers will appear under the key
button. Press the key button several times and
check if the same number appears each time.)
6. Press MEM2 button. (The data for step 5 is
registered in MEM2.)
7. Make sure the difference of numbers for
MEM1 and MEM2 is 6 or more.
(The mean number of MEM1 and MEM2 will
be the standard data.)
8. Press OK button.
9. Turn the Power OFF.
30
Summary of Contents for Memory Craft 10001
Page 1: ...SERVICING MANUAL...
Page 42: ...40...