To replace and adjust the threader plate
If the needle threader plate is broken or bent, replace it as follows:
(TO REPLACE)
1. Turn the balance wheel toward you until the needle bar reaches its highest position and
lower the needle threader knob (D) as far as it will go.
2. Loosen screw (E) and replace the needle threader plate (F) (See *** A ***).
(TO ADJUST)
3. If the hook (G) touches the right or left side of the needle eye (H), loosen screw (E) and
move the needle threader plate (F) (See *** B ***).
4. If the hook (G) touches the top or bottom of the needle eye (H), loosen set screw (J) and
move the position set plate (I) (See *** C ***).