10
TO ADJUST THE NEEDLE HEIGHT
Correct setting:
The distance between the tip of needle and the surface of needle plate should be 11.6 mm to
12.2 mm when the needle bar is at the highest position.
To adjust:
1: Remove the face plate unit.
2: Turn the handwheel toward you with your hand, and set the needle bar at the highest position.
3: Loosen the set screw A to adjust the height, and tighten set screw A after the adjustment is
done.
4: Turn the handwheel toward you by one complete turn, and recheck the needle bar height.
5: Attach the face plate unit.