11
TO ADJUST THE PRESSER BAR HEIGHT
Correct setting:
The distance between the surface of needle plate and bottom of presser foot should be 4.7mm to 5.3 mm
when the presser bar lifter is raised.
To adjust:
1: Remove the face plate unit.
2: Remove set screws A to remove the lamp socket unit.
3: Raise the presser bar lifter, and loosen the set screw B.
Then adjust the presser bar height, the side of presser foot should be parallel with the slit of needle
plate.
4: Tighten the set screw B.
5: Tighten the set screw A.
6: Attach the face plate unit.