12
(C)
(A)
(D)
(E)
(F)
6.0 MM
(B)
MECHANICAL ADJUSTMENT
PRESSER BAR HEIGHT AND ALIGNMENT
TO CHECK:
1. RAISE THE PRESSER FOOT LIFTER (A).
2. THE DISTANCE BETWEEN THE PRESSER FOOT (D) AND THE NEEDLE PLATE (E) SHOULD
BE 6.0 MM (0.24˝).
ADJUSTMENT PROCEDURE:
1. REMOVE THE FACE COVER (SEE PAGE 7).
2. REMOVE THE SETSCREWS (B) AND THE LAMP SOCKET, THEN LOOSEN THE SCREW (C)
ON THE PRESSER BAR HOLDER.
ADjUST THE DISTANCE BETWEEN THE PRESSER FOOT (D) AND THE NEEDLE PLATE (D)
TO 6.0 MM (0.24˝).
3. TIGHTEN THE SCREW (C) SECURELY.
4. TIGHTEN THE SETSCREW (B) TO SECURE THE LAMP SOCKET.
5. ATTACH THE FACE COVER.
NOTE:
WHEN YOU TIGHTEN THE SCREW (C), MAKE SURE THAT BOTH SIDES OF THE PRESSER
FOOT ARE PARALLEL TO THE FEED DOG SLOTS (F) IN THE NEEDLE PLATE (E).