0 : Digital setting, P0-08 sets the initial
value, no memory when power off
0: Digital setting, P0-08 sets the initial
value, no memory when power off
Operation panel
,
adjustment
1: Digital setting, P0-08 setting initial
value, power-off memory
1: Digital setting, P0-08 setting initial
value, power-off memory
Terminal UP/DN
adjustment
2: AI1
2: AI1
3: AI2
3: AI2
4: AI3 keyboard potentiometer
4: AI3 keyboard potentiometer
DI5terminal P4-04 is
set to 30
5:PLUSEpulse setting (DI5)
5:PLUSE pulse setting (DI5)
6:Multi-segment instructions
6:Multi-segment instructions
7:Simple PLC
7:Simple PLC
8:PID
8:PID
9:Communication setting
9:Communication setting
5.1.3 Working status
FC100P working
status
illustrate
downtime
After the inverter is powered on and initialized, if there is no running command input, or
after the stop command is executed during running, the U/V/W terminals of the inverter
will have no output, and the running status indicator on the operation panel will flash.
Operating status
After the inverter receives the running command, the U/V/W terminals of the inverter start
to output, and the running status indicator on the operation panel is always on.
Motor parameter
self-tuning
status
P1-37 is set to 1 or 2 or 3, the inverter receives the running command and enters the
motor parameter self-tuning state.
After the self-tuning is completed, it will automatically enter the shutdown state.
System running
status
Refers to the state where the U/V/W terminals of the inverter have output or zero-
frequency blocked output or sleep and wait for restart.
In this state, the running status indicator on the operation panel is always on, and the LED
flashes to display the parameters in the stop state, and the parameters that cannot be
modified during the operation of the inverter cannot be modified.
5.1.4 Operating mode
FC100P
operating mode
Illustrate
Process PID
adjustment
operation
process PID adjustment operation function is valid ( P0-03=8 ), the inverter will select the
process PID adjustment operation mode, that is, perform PID adjustment according to the
setting and feedback amount ( PA group needs to be set).
Multi-stage
speed operation
the logical combination of DI terminals (12- 1No. 5 function), select the multi-stage
frequency 1-1 6 ( PC.00-PC.15) for multi-stage speed operation.
Simple PLC
operation
simple PLC function selection is valid ( P0-03 =7), the inverter will run in the simple PLC
mode, and the inverter will run according to the preset operating parameters (see the
parameters of the PC group ) .
5
Janson Controls Technologies(Shenzhen) Co.,Limited
Chapter5 Operation
FC100P Series Manual V1.0