background image

POPULUS P – Access controller  

 

 

 

 

5/2014 

Black line 

www.codeks.eu 

 

 

 

 

 

 

 

                                         

 
 
 
 
 
 
 
 

POPULUS P – ACCESS CONTROLLER 

 

The Populus P is an access controller that controls up to 8 readers 

and 4 outputs for electric strikes. It is designed for residential and 

business buildings, offices, shops, etc.  

 

The entire set-up procedure is carried out with the software. The 

controller allows access for up to 16000 users. It is intended for 

controlling entries, exits and passes of users in the system and 
controlling sliding doors, ramp, el. strike, turning alarm on/off…  It 

needs to be set with BLOCKER, V7 or CODEKS software. 

 

 

It may also be used as a standalone controller. In this case, the 

entire set-up procedure is carried out with master card or code. 
User cards and codes can either be registered or deleted. The 

controller allows access for up to 500 users (1 master card + 500 

user cards or codes). 

 

The SDK is also available for this controller. If a user or software 

producer wants to develop its own application, please contact us.  

 

TECHNICAL DATA 

POPULUS P-1-3P and POPULUS P-1-3P-NET 

Readers 

1x direct or Wiegand, 1x protocol 

Inputs 

1x door status, 1x button  

Outputs 

1x max. 0.5 A active=GND 

Relays 

1x 5A   60V DC 

 

POPULUS P-2-3P and POPULUS P-2-3P-NET 

Readers 

2x direct or Wiegand, 2x protocol 

Inputs 

2x door status, 2x button  

Outputs 

2x max. 0.5 A active=GND 

Relays 

2x 5A   60V DC 

 

POPULUS P-4-3P and POPULUS P-4-3P-NET 

Readers 

4x direct or Wiegand, 4x protocol 

Inputs 

4x door status, 4x button  

Outputs 

4x max. 0.5 A active=GND 

Relays 

4x 5A   60V DC 

*if Populus P is in Spider mode, the same data applies 

 

Common features 

Input voltage 

110 – 230 V AC  50–60 Hz 

Output voltage 

13.8 V DC   

Primary fuse  

(F100) T1AL,  250 V (5x20mm) 

Current consumption 

Up to 2W 

Humidity 

10-80 %, non-condensing 

Dimensions (mm) 

222x222x80 (WxHxD) 

Operating temperature 

From -20°C to 40°C 

Communication 

RS485 or Ethernet 

Clock 

Real time clock, battery backup 

(max. ten hours) 

Operation at an altitude of 

<2000m 

Appliance class  

Class II - This is a class A 

product. In a domestic 

environment this product may 

cause radio interference in which 

case the user may be required to 

take adequate measures. 

 

CONNECTOR DESCRIPTION 

Connectors are marked on the circuit board with AC, LAN, SYS, 

COM, RDR and DOOR

 

CONNECTOR AC – Power supply 

Contact 

Description  

Specification 

1  

AC 

Power supply  

110 – 230 V AC   

50–60 Hz 

 

CONNECTOR LAN – Ethernet connection 

Contact 

Description  

Specification 

1  

LAN 

Ethernet 

 

CONNECTOR SYS – backup battery connection 

Contact 

Description  

Specification 

1  

BAT 

12 V DC from battery  

2  

GND 

Ground 

3  

12V  

Max. 0.5 A  

4  

GND 

Ground 

 

CONNECTOR COM – RS485 communication connection 

Contact 

Description  

Specification 

1  

CA 

RS485 A line 

2  

CB 

RS485 B line 

3  

CA  

RS485 A line 

4  

CB  

RS485 B line 

 

CONNECTOR RDR1, RDR2, RDR3, RDR4 – reader connection 

Contact 

Description  

Specification 

1  

12V 

12 V DC output 

2  

GND 

Ground 

3  

D0  

Data 0  

4  

D1 

Data 1 

BUZ  

Buzzer output 

6  

LED 

LED output  

7  

XA – RS485 XA line 

For protocol reader 

8  

XB – RS485 XB line 

For protocol reader 

 

CONNECTOR DOOR1, DOOR2, DOOR3, DOOR4 – sensor, 

button, el. strike and relay connections 

Contact 

Description  

Specification 

1  

SWITCH 

Door status switch input  

active=GND 

2  

GND 

Ground 

3  

BUTTON 

Push button input

 

active=GND 

4  

12V 

12 V DC output 

LOCK 

El. strike output 

active=GND 

6  

NO 

Relay – open contact  

7  

MIDDLE 

Relay – middle 

8  

NC 

Relay – closed contact 

 

Power Supply 

The controller can operate within a 110-230V AC, 50–60Hz input 

range. The output power of the in-built power supply is 30W, 13.8V 

fulltime. The power supply has protection against both short 

circuits and current overload. In the event of protection activation, 

the power will be switched off for 5s. If this is repeated 20 times, 

the controller will switch off until electrical resetting takes place 

(unplugging from mains voltage). This protection is activated if 

external consumption exceeds 2A. 

 

An appropriate disconnect device should be provided external to 

the equipment. 

A multi-strand/stranded flexible wires connected to 

the unit mains input require ferrules. 

 

 

 