background image

REGIS F – Access or time and attendance controller with integrated fingerprint reader

 

 

 

 

 

9/2016 

Black line 

www.jantar.si 

 

Environment:

 

It is designed for indoor, non-condensing, applications. Do not 
expose the controller to direct contact with the elements such as 
rain, snow or sunlight. 

If the plastic housing is in a different color 

than black, then there is a chance that the color will change (to 
some extend) in a few months or years if exposed to direct 
sunlight.

 The sensor surface is hard and extremely robust, and will 

withstand years of normal wear-and-tear. Do not subject the 
sensor to sharp or hard objects since this might cause permanent 
damage. Cleaning should be done with a lint-free cotton textile. Do 
not subject the sensor surface to mechanical force.  
You must assure good cable joints, protected against moisture, 
otherwise corrosion may damage the controller. Damage in such 
cases is not covered by the warranty.  
 

Installation:  

Install the holder

 

on the wall with two supplied screws. Use 

diagonal holes - it enables a small correction of the position of the 
controller (up, down, left, right). Connect wires to the controller 
and place it

 

on the holder and press – after you hear the click, it is 

fixed. If you want to remove the controller from the holder, put the 
screwdriver into the side hole in push a little to move the pin 
holding the controller.

 

 

 

AS AN ACCESS OR TIME AND ATTENDANCE 

CONTROLLER 

 

Access controller 

As an access controller, it is intended for controlling entries, exits 
and passes of users in the system and controlling sliding doors, 
ramp, el. strike, turning alarm on/off…  It needs to be set with 
CODEKS software.  
Set the software according to your requirements (time tables, 
users...) and send the tables. The keypad will serve for entering 
user codes. 
 

Time and attendance controller 

As a time and attendance controller, it is intended to register the 
employee’s arrivals and exits from work, lunch break, private and 
business exits, sick leave... It needs to be set with CODEKS 
software. In software you need to choose option “Time and 
attendance” for controller and reader. Set the software according 
to your requirements (time tables, users...) and send the tables. 
The keypad will serve for choosing different time intervals (private, 
business…). 

The default address of the controller is the same as the last 
digit of the IP address. E.g. if the IP address of the 
controller is 192.168.110.105, then the controller's address 
is 105. 
If you have more controllers on the communication line, 
don’t duplicate addresses. 

 

 

Communication  

Ethernet: 

Connect the controller to the computer through your LAN via 
connector on the back side. Please check the connection scheme 
which can be found on Jantar Forum.  
Use at least UTP CAT 5e cable. Adjust network settings of the 
controller using the Codeks Device Manager software so that it will 
function properly in your network. Please consult Codeks Device 
Manager’s manual.  

 
RS485: 

Connect the controller to the computer, with one of the power 
supplies, with communication converter, from the Spider family: 
Spider W5-USB, Spider W5-NET, Spider W40+NET.  
The RS485 communication bus is used between the controllers and 
Jantar software. Up to 128 controllers can be lined up into one 
communication line. The maximum length of the communication  
 

 
line is 1000 cable meters. It is recommended that you use an FTP 
or S-FTP cable. Only a serial connection of controllers in a single  
 
communication line is allowed. 

Star (parallel) connection is not 

allowed

.  

All shields of S-FTP cables must be wired together and at 

one 

point

 connected to the earth. Individual connections to the earth 

are not allowed. Do not connect the shield of the cable to the 
ground of the controller. 

 
In the event of problems in communication, a termination 
resistor needs to be added. We recommend using 120 Ohm 
resistors on each side of the cable. Converters are, on the 
RS485 side, protected with slow-blow fuses and transient 
voltage suppressors.

 

 
Changing back to standalone controller from access 
controller: 

In the Codeks Device Manager software do the “Brainwash” of the 
controller. Address of the controller’s switches back to 255.  

 
Correct and incorrect position of the finger on the sensor 

Correct:                                   Incorrect: 

 

 

 
 

 

 
 

 
 

 
 

ORDERING CODES 

 
REGIS

 [box]-[card]-[software]  

Box:  

F

 

Card:  

– reading frequency 125kHz (cards)  

– reading frequency 13.56MHz (cards)  

Model:   

B

 – Black line

 

 

 

Code 

Description 

REGIS F-1-B 

Standalone, access or time and attendance 

controller in 

F

 box, capacitive touch screen 

display, Frequency 125kHz, fingerprint reader 
for CODEKS software, Integrated Ethernet 

REGIS F-3-B 

Standalone, access or time and attendance 
controller in 

F

 box, capacitive touch screen 

display, Frequency 13.56MHz, fingerprint reader, 

for CODEKS software, Integrated Ethernet 

 
 

OTHER 

 
Warranty only applies when the controller Regis is used with power 
supply or/and communication converter from the Spider family. 
 
Please read through our warranty and disclaimer statements. 

 

Connection scheme and additional support for the use of this 
product can be found on: 

http://www.jantar.si/forum/en

 

 
CONTACT:

 

Jantar d.o.o. 
Kranjska cesta 24 
4202 Naklo 

 

 

web: 

www.jantar.si

 

SLOVENIA 

 

 

mail: 

sales@jantar.si 

Reviews: