REGIS F – Access or time and attendance controller with integrated fingerprint reader
9/2016
Black line
www.jantar.si
Environment:
It is designed for indoor, non-condensing, applications. Do not
expose the controller to direct contact with the elements such as
rain, snow or sunlight.
If the plastic housing is in a different color
than black, then there is a chance that the color will change (to
some extend) in a few months or years if exposed to direct
sunlight.
The sensor surface is hard and extremely robust, and will
withstand years of normal wear-and-tear. Do not subject the
sensor to sharp or hard objects since this might cause permanent
damage. Cleaning should be done with a lint-free cotton textile. Do
not subject the sensor surface to mechanical force.
You must assure good cable joints, protected against moisture,
otherwise corrosion may damage the controller. Damage in such
cases is not covered by the warranty.
Installation:
Install the holder
on the wall with two supplied screws. Use
diagonal holes - it enables a small correction of the position of the
controller (up, down, left, right). Connect wires to the controller
and place it
on the holder and press – after you hear the click, it is
fixed. If you want to remove the controller from the holder, put the
screwdriver into the side hole in push a little to move the pin
holding the controller.
AS AN ACCESS OR TIME AND ATTENDANCE
CONTROLLER
Access controller
As an access controller, it is intended for controlling entries, exits
and passes of users in the system and controlling sliding doors,
ramp, el. strike, turning alarm on/off… It needs to be set with
CODEKS software.
Set the software according to your requirements (time tables,
users...) and send the tables. The keypad will serve for entering
user codes.
Time and attendance controller
As a time and attendance controller, it is intended to register the
employee’s arrivals and exits from work, lunch break, private and
business exits, sick leave... It needs to be set with CODEKS
software. In software you need to choose option “Time and
attendance” for controller and reader. Set the software according
to your requirements (time tables, users...) and send the tables.
The keypad will serve for choosing different time intervals (private,
business…).
The default address of the controller is the same as the last
digit of the IP address. E.g. if the IP address of the
controller is 192.168.110.105, then the controller's address
is 105.
If you have more controllers on the communication line,
don’t duplicate addresses.
Communication
Ethernet:
Connect the controller to the computer through your LAN via
connector on the back side. Please check the connection scheme
which can be found on Jantar Forum.
Use at least UTP CAT 5e cable. Adjust network settings of the
controller using the Codeks Device Manager software so that it will
function properly in your network. Please consult Codeks Device
Manager’s manual.
RS485:
Connect the controller to the computer, with one of the power
supplies, with communication converter, from the Spider family:
Spider W5-USB, Spider W5-NET, Spider W40+NET.
The RS485 communication bus is used between the controllers and
Jantar software. Up to 128 controllers can be lined up into one
communication line. The maximum length of the communication
line is 1000 cable meters. It is recommended that you use an FTP
or S-FTP cable. Only a serial connection of controllers in a single
communication line is allowed.
Star (parallel) connection is not
allowed
.
All shields of S-FTP cables must be wired together and at
one
point
connected to the earth. Individual connections to the earth
are not allowed. Do not connect the shield of the cable to the
ground of the controller.
In the event of problems in communication, a termination
resistor needs to be added. We recommend using 120 Ohm
resistors on each side of the cable. Converters are, on the
RS485 side, protected with slow-blow fuses and transient
voltage suppressors.
Changing back to standalone controller from access
controller:
In the Codeks Device Manager software do the “Brainwash” of the
controller. Address of the controller’s switches back to 255.
Correct and incorrect position of the finger on the sensor
Correct: Incorrect:
ORDERING CODES
REGIS
[box]-[card]-[software]
Box:
F
Card:
1
– reading frequency 125kHz (cards)
3
– reading frequency 13.56MHz (cards)
Model:
B
– Black line
Code
Description
REGIS F-1-B
Standalone, access or time and attendance
controller in
F
box, capacitive touch screen
display, Frequency 125kHz, fingerprint reader
for CODEKS software, Integrated Ethernet
REGIS F-3-B
Standalone, access or time and attendance
controller in
F
box, capacitive touch screen
display, Frequency 13.56MHz, fingerprint reader,
for CODEKS software, Integrated Ethernet
OTHER
Warranty only applies when the controller Regis is used with power
supply or/and communication converter from the Spider family.
Please read through our warranty and disclaimer statements.
Connection scheme and additional support for the use of this
product can be found on:
CONTACT:
Jantar d.o.o.
Kranjska cesta 24
4202 Naklo
SLOVENIA