SPIDER W40 – Power supply for 2 controllers with battery support 

 

 

 

 

5/2014 

Black line 

www.codeks.eu 

 

 

 

 

 

 

 

                                         

 
 
 
 
 
 
 
 

SPIDER W40 – POWER SUPPLY FOR 2 
CONTROLLERS WITH BATTERY SUPPORT 

 

The Spider W40 is a 30 watt power supply for 2 controllers and el. 

strikes or el. magnets. It is designed for residential and business 

buildings, offices, shops, etc.  

It is intended to power controllers for time and attendance, access 

controllers and standalone controllers. 

 
The special version of the Spider W40-NET has a built-in TCP/IP 

converter, which enables communication between the connected 

controllers (and additional controllers in the communication line) 

and the access control program via LAN/WAN. 

 

TECHNICAL DATA 

Spider W40 and Spider W40-NET 

Input voltage 

110 – 230 V AC  50–60 Hz 

Output voltage 

13.8 V DC   

Primary fuse 

(F100) T1AL,  250 V (5x20mm) 

Current consumption 

Up to 1W 

Humidity 

10-80 %, non-condensing 

Dimensions (mm) 

180x180x80 (WxHxD) 

Operating temperature 

From -20°C to 70°C 

Communication 

RS485 or Ethernet 

Relay 

2x 5A 60V DC 

Operation at an altitude of 

<2000m 

Appliance class  

Class II - This is a class A 

product. In a domestic 

environment this product may 

cause radio interference in which 

case the user may be required to 

take adequate measures. 

 

Power Supply 

The device can operate within a 110-230V AC, 50–60Hz input 

range. The output power of the in-built power supply is 30W, 13.8V 

fulltime. The power supply has protection against both short 

circuits and current overload. In the case of protection activation, 

the power will be switched off for 5s. If this is repeated 20 times, 

the power supply will switch off until electrical resetting takes place 

(unplugging from mains voltage). This protection is activated if 

external consumption exceeds 2A. 

 

An appropriate disconnect device should be provided external to 

the equipment. A multi-strand/stranded flexible wires connected to 

the unit mains input require ferrules. 

 

2.3Ah battery support is included with a charging limit of 13.8 V DC 

and shut down at 10.5V. The charging time of an empty battery is 

approximately 4 hours. The charging voltage and current are 13.8 

V DC and max. 0.625 A. 2.3Ah battery can be installed in the box. 

Larger external 12V batteries, such as 7Ah, may also be connected 

but recharging times will be longer. When operating from battery, 

the output voltage will drop from 13.8V to 10.5V according to 

consumption at which point Spider W40 will turn off. Risk of 

explosion if battery is replaced by an incorrect type. Dispose of 

used batteries according to the manufacturer's instructions. 

 

 

 

Voltage drops 

When you connect devices to the power supply, use a cable of at 

least 0.2mm

2

 diameter. Take into consideration the fact that this 

cable has a resistance of approximately 9ohm per 100m. You 

should have a minimum of 10V for power supply at device point 

(for our controllers). For total case scenario, consider also the 

supply voltage drop when operating on a battery. 

 
 
CONNECTOR DESCRIPTION 

Connectors are marked on the circuit board with AC, LAN, POE, 

PWR, TMP, DEV1 and DEV2

 

CONNECTOR AC – power supply 

Contact 

Description  

Specification 

1  

AC 

Power supply  

110 – 230 V AC   

50–60 Hz 

 

CONNECTOR LAN – Ethernet connection 

Contact 

Description  

Specification 

1  

LAN 

Ethernet 

 

CONNECTOR POE – Ethernet conn Power supply 

Contact 

Description  

Specification 

1  

POE 

Et Power supply 

12 V DC 

 

CONNECTOR PWR – backup battery connection, 12 V DC 

output, RS485 communication line (CA, CB) 

Contact 

Description  

Specification 

1  

BAT 

12 V DC from battery  

2  

GND 

Ground 

3  

12V  

Output Max. 0.5 A  

4  

GND 

Ground 

CA 

RS485 A line 

6  

CB 

RS485 B line 

7  

CA  

RS485 A line 

8  

CB  

RS485 B line 

 

CONNECTOR DEV1 – connection for controller and el. strike 

or other controlled device 

Contact 

Description   Specification 

1  

12V  

Max. 0.3 A. Connect 12V DC to 

controller, el. strike, other device 

(siren...). 

2  

GND 

Ground. Connect ground to 

controller. 

3  

LOCK  

Input for el. strike (also controls 1. 

relay). Connect ground to el. strike 

and O0 from controller. 

4  

TMP 

Input for alarm. Connect ground 

from other device (siren...) and O1 
from controller (with alarm output). 

SWITCH 

Input for door status switch. 

Connect magnet for door status 

and I0 from controller. 

6  

BUTTON 

Input for push button. Connect 

push button and I1 from controller. 

7  

CA 

Connect RS485 communication 

from controller. 

8  

CB 

Connect RS485 communication 

from controller. 

9  

OPEN 

Relay – open contact (NO) 

10  

MIDDLE 

Relay – middle contact 

 

 

 

 

Reviews: