background image

POTSwap User Guide JA16-EVDO-UM

    

 Page 14    Rev: P07    Date: 08/01/16

© Copyright 2016 Janus Remote Communications   

Specifications subject to change without notice

   All Rights Reserved   See website for latest revision.    Not intended for life support applications.

 

5 External Interfaces continued

5.2 Rear Panel continued

SERIAL PORT PINS

PIN NUMBER  

 

FUNCTION 

 

NEMONIC 

 

DIRECTION

   

 

 

CARRIER DETECT 

 

CD 

 

OUTPUT

   

 

 

RECEIVED DATA 

 

RX 

 

OUTPUT

   

 

 

TANSMITTED DATA 

 

TX 

 

INPUT

   

 

 

DATA TERMINAL READY 

DTR 

 

INPUT

   

 

 

GROUND 

 

GND 

 

-----

   

 

 

DATA SET READY 

 

DSR 

 

OUTPUT

   

 

 

READY TO SEND 

 

RTS 

 

INPUT

   

 

 

CLEAR TO SEND 

 

CTS 

 

OUTPUT

   

 

 

RING INDICATOR 

 

RI 

 

OUTPUT

Default communications protocol is 115200 baud, 8-N-1 (8 data bits, no parity, 1 stop bit) with no handshaking.

SERIAL COMMUNICATION PROTOCOL:

PARAMETER 

 

SETTING

Baud rate 

 

115200

Data bits 

 

8

Parity bit 

 

None

Stop bits 

 

1

Handshaking 

 

None

6 Provisioning

A new POTSwap (model EVDO910PS) will require provisioning by the cellular carrier before it can be used. 
Provisioning occurs ‘over the air’ and sets up the cellular radio in the POTSwap to operate on the carrier’s network.  
The phone number of the cellular radio is installed during provisioning.

When negotiating a service agreement with a cellular carrier, the MEID (Mobile Equipment IDentifier) of the POTSwap 
cellular radio will be required.  This 14 character code can be found on the label on the top of the POTSwap 
enclosure.  It can also be obtained using the ‘IDENTIFY’ command from the terminal configuration menu.  See 
section 4 - Configuration.

Provisioning can be performed by dialing *228 from a connected telephone device or from the terminal configuration 
menu by entering the ‘PROVISION’ command. A signal strength indication of 3 or 4 LED ‘bars’ is recommended.  

When provisioning using the *228 dialing option, a dial tone must be present before dialing.  During provisioning, the 
cellular carrier will provide an audio message about the success or failure of the provisioning process.  

When provisioning using the ‘PROVISION’ command from the terminal configuration menu, the procedure can be 
monitored by observing the output to the terminal. “Provisioning failed” will be reported if the provisioning was not 
successful. Following provisioning using the terminal configuration menu, enter the REBOOT command restart the unit.

Summary of Contents for POTSwap EVDO910PS

Page 1: ...POTSwap EVDO910PS Version Product User Manual Bulletin JA16 EVDO UM Revision P07 Date 01 Aug 2016 ...

Page 2: ...n 5 6 3 1 Set up 3 2 Voice Operation 3 2 1 Placing Calls Manual Telephones Automated Dialers 3 2 2 Receiving Calls 3 3 3 Call Disconnect 4 Configuration 7 10 5 External Interface 11 14 5 1 Front Panel Received Signal Strength Indicator LED Operational indicators POWER RED LED CELLULAR YELLOW LED STATUS GREEN LED PUSH BUTTONS PHONE FXS Connector 5 2 Rear Panel Power connectors Antenna connectors Se...

Page 3: ...es not make any warranty as to the information contained herein and does not accept any liability for any injury loss or damage of any kind incurred by use of or reliance upon the information Connor Winfield disclaims any and all responsibility for the application of the devices characterized in this document and notes that the application of the device must comply with the safety standards of the...

Page 4: ...d can be configured to emulate all international telephone line standards Wireless connectivity is provided by the Janus line of Plug In Terminus terminal modems which provide support for all current mobile network technologies with service available from numerous wireless carriers Configuration of the POTSwap can be achieved via a local serial interface connection 2 Plug In Terminus Cellular comm...

Page 5: ... a rapidly flashing GREEN STATUS LED a blinking CELLULAR LED and a steady signal strength indication on the Received Signal Strength LED stack 4 A POTSwap with a newly activated account with a cellular carrier must first be provisioned This can be accomplished by dialing 228 from a telephone device attached to the POTSwap see section 6 Provisioning 3 2 Voice Operation Voice operation requires a st...

Page 6: ...lacing the connected telephone equipment on hook If a cellular call is terminated on the carrier side the result of a connected party ending the call or due to loss of signal the POTSwap will use an Open Switching Interval to aid in disconnecting automated type telephone equipment It removes the voltage from the phone line connection for a short time to signal that the call has been terminated The...

Page 7: ...11 Voice Calling where system configuration permit allow Installer responsible for validation of service WireLine_Open 25 Speaker Level 25 Microphone Level 1 Echo Cancellation 900 Open Switching Interval 30000 Dialing Tone Timeout 4000 Dialing Digit Timeout 6000 Busy Dwell Timeout 0 Fixed Format Dialing 0 Fail Over Mode 2 ADC Gain 4 DAC Gain 2 Loop Current Limit 0 Loop Closure Sensing Type 8 Loop ...

Page 8: ...t up and operation of the POTSwap DEBUG xx DO NOT USE Factory use only DUMP Adr Len DO NOT USE Factory use only XMODEM Used for firmware upgrades REBOOT Entering REBOOT will restart the POTSwap similar to pressing the RESET button CONFIG Entering CONFIG will cause the configuration menu to be output Janus Remote Communications WireLine II Board POTSwap Configuration Microphone Level 25 0 31 Speake...

Page 9: ...ff hook Exceeding the time limit will cause Open Switching Interval to be generated Dialing Digit Timeout2 6000 250 15000 Sets time limit for time between entering dialing digits milliseconds Exceeding the time limit will cause Open Switching Interval to be generated Busy Dwell Timeout2 6000 1000 30000 Sets length of time a busy tone is generated locally on calls milliseconds where the cellular ca...

Page 10: ...er 4 Available on firmware 160714 and higher D DEFAULTS Command Entering the D command will change all of the settings back to the factory defaults These settings will not be saved unless the X Exit and Save command is issued Older versions of firmware will request that the POTSwap be restarted to effect the changes current versions will restart automatically X EXIT AND SAVE Command Entering the X...

Page 11: ...rom bottom to top and back in a scanning manner GPS INDICATOR The bottom 1 Marginal LED on the RSSI indicator will blink several times for 1 second every 10 seconds to indicate a GPS location fix is available This indication is independent of the cellular signal strength indication See section 7 GPS LED Operational indicators LED LED COLOR INDICATION POWER Red Power status CELLULAR Yellow Cellular...

Page 12: ...ializing PUSH BUTTONS Three push buttons are provided on the front panel of the POTSwap These can be operated with a small diameter object such as a paperclip There is tactile feedback that indicates when the push button has been operated Applying pressure to the push buttons beyond the point at which they actuate can damage the switch Currently the SELECT and MODE push buttons are not supported T...

Page 13: ...including screw terminal spring clamp and crimp terminal type See Section 9 Compatible Terminal Block Connectors Circular Jack The circular DC jack has a 6 mm hole diameter and a 2 mm center pin It is designed to accept a 5 5 mm diameter plug with a 2 1 mm center hole and a 8 5 mm barrel length The center pin is the positive terminal Antenna Connectors CELLULAR A standard 50 ohm SMA connector is p...

Page 14: ...o operate on the carrier s network The phone number of the cellular radio is installed during provisioning When negotiating a service agreement with a cellular carrier the MEID Mobile Equipment IDentifier of the POTSwap cellular radio will be required This 14 character code can be found on the label on the top of the POTSwap enclosure It can also be obtained using the IDENTIFY command from the ter...

Page 15: ...A SS Set MN HA SS Set OK OK after profile output Check MDN Found MDN MDN 2025551212 MDN 2025551212 appears valid OK after reading MDN Provision the module Received OTASP 0 Start OTASP Received OTASP 1 Start OTASP Commit Received OTASP 2 End OTASP NO CARRIER after provisioning done 23077 Waiting for shutdown Shutdown complete done 1094 Wait for re start Re start complete done 6407 Wait for registra...

Page 16: ...If the antenna must be indoors placement as near as possible to a window is preferable Receiving a GPS location fix deep inside buildings or in dense urban environments street canyons is normally not possible 7 4 GPS Troubleshooting With a terminal attached to the SERIAL port debug messages are available that can be used to monitor the GPS operation See section 4 Configuration for information on a...

Page 17: ...rimp connector type terminal blocks Features Parameters Description SLIC Performs all BORSCHT functions Battery supply to subscriber line Overvoltage protection Ringing current supply Supervision of subscriber terminal Coder and decoder Hybrid 2 wire to 4 wire conversion Testing DTMF encoding and decoding REN 5 at 100 ft 30m Voice Voice over cellular Cellular Connection EVDO910PS model supports CD...

Page 18: ...ple of compatible connectors TYPE MANUFACTURER PART NO DESCRIPTION Screw Terminal TE Connectivity1 796634 2 vertical screw horizontal plug TE Connectivity 1986484 2 horizontal screw vertical plug Molex 395300002 vertical screw horizontal plug Molex 395332002 horizontal screw vertical plug Weidmuller 1943580000 vertical screw horizontal plug Spring Clamp Weidmuller 1013680000 orange Weidmuller 1013...

Page 19: ...E GPRS GSM AT T and PTCRB EVDO910PS v3 00 TAGFNG EV DO Verizon 11 Accessories The following accessories are available from Janus Remote Communications ACCESSORY DESCRIPTION JANUS STORE PART NUMBER POWER SUPPLY Wall transformer with circular DC connector 12V 2A MC 0004 CELLULAR ANTENNA Indoor dual band CDMA EVDO ANT 0073 GPS ANTENNA GPS Active Antenna Magnetic Mount Waterproof 10 ft SMA ANT 0030 TE...

Page 20: ...ote P00 11 23 13 Preliminary POTSwap User Manual Release P01 03 03 14 Overall Product Update Changes P02 05 14 14 Updated to CDMA Version Only EVDO910PS P03 10 21 14 Updated 3 2 Voice Operation 4 0 Configuration 6 0 Provisioning and Misc edits P04 11 12 14 Updates to 6 0 Provisioning and 10 0 Accessories P05 08 11 15 Update to Enclosure and Dimensions P06 09 08 15 Operation Configuration Interface...

Reviews: