5 External Interfaces continued
5.2 Rear Panel continued
SERIAL PORT PINS
PIN NUMBER
FUNCTION
NEMONIC
DIRECTION
1
CARRIER DETECT
CD
OUTPUT
2
RECEIVED DATA
RX
OUTPUT
3
TANSMITTED DATA
TX
INPUT
4
DATA TERMINAL READY
DTR
INPUT
5
GROUND
GND
-----
6
DATA SET READY
DSR
OUTPUT
7
READY TO SEND
RTS
INPUT
8
CLEAR TO SEND
CTS
OUTPUT
9
RING INDICATOR
RI
OUTPUT
Default communications protocol is 115200 baud, 8-N-1 (8 data bits, no parity, 1 stop bit) with no handshaking.
SERIAL COMMUNICATION PROTOCOL:
PARAMETER
SETTING
Baud rate
115200
Data bits
8
Parity bit
None
Stop bits
1
Handshaking
None
6 Provisioning
A new POTSwap (model EVDO910PS) will require provisioning by the cellular carrier before it can be used.
Provisioning occurs ‘over the air’ and sets up the cellular radio in the POTSwap to operate on the carrier’s network.
The phone number of the cellular radio is installed during provisioning.
When negotiating a service agreement with a cellular carrier, the MEID (Mobile Equipment IDentifier) of the POTSwap
cellular radio will be required. This 14 character code can be found on the label on the top of the POTSwap
enclosure. It can also be obtained using the ‘IDENTIFY’ command from the terminal configuration menu. See
section 4 - Configuration.
Provisioning can be performed by dialing *228 from a connected telephone device or from the terminal configuration
menu by entering the ‘PROVISION’ command. A signal strength indication of 3 or 4 LED ‘bars’ is recommended.
When provisioning using the *228 dialing option, a dial tone must be present before dialing. During provisioning, the
cellular carrier will provide an audio message about the success or failure of the provisioning process.
When provisioning using the ‘PROVISION’ command from the terminal configuration menu, the procedure can be
monitored by observing the output to the terminal. “Provisioning failed” will be reported if the provisioning was not
successful. Following provisioning using the terminal configuration menu, enter the REBOOT command restart the unit.