106
106
13.4 VISUALIZATION of the DATA of INTERNAL/EXTERNAL PLU
It’s possible to visualize on display the programming data of internal PLU (programmed
on the ECR’s memory) and the data of external PLU (on PC) besides the bar-codes read
with the scanner can be showed on display ; this function can be activated in the "S" mode.
In order to activate the function of control of internal PLU and PB to execute :
(0)
directly from the "Reg." mode, it will be obviously necessary that there aren’t open receipts
(the function "S" does not have secrets codes for the activation).
VERIFICATION OF INTERNAL/EXTERNAL "PLU" DATA:
After to have executed the above described operation to continue as following :
- -
OPERATION -- -- DISPLAY --
1) (NNN..N) PLU NNN..N
=
PLU code
4901201202155
PLU code with CHECK DIGIT
Note:
The sequence (NNN... N) PLU can be replaced from the reading through
scanner of the product’s bar-code or from the pression of direct PLU key
2) PLU
Department No.
01
3) PLU
PLU price
850
Note: if the PLU doesn’t exist on memory, the point 2 execution will cause an ERROR.
13.5 "CALCULATOR" FUNCTION
On J3500 is possible to activate the function "CALCULATOR", that allows to execute,
on the ECR’s display (without therefore that nothing it is printed on paper), the four
operations (addition, subtraction, division and multiplication).
Besides not executing not any type of printing, the operations executed by the
"CALCULATOR" mode don’t modify neither not any type of totalizer and/or counter in the
ECR’s memory.
In order to activate this function it will be necessary to put on the ECR’s keyboard five
keys "+", "-", "X", "
÷
" and "=", for the positioning of these keys you have to see the
"Programming Manual" (keys respective codes 066, 067, 068, 069 and 070).
With the key-pad above indicated for the "CALCULATOR" function, it will be possible
to be operated like on a normal calculator, the input digits and the result of the operations
will be visualized either on the operating’s display than on customer’s display.
In order to remove eventual amounts inserted in wrong way or eventual error
condictions, normal "CL" key present in ECR’s keyboard can be used.
Operation Calculator :
R (PPPPPPPPP) +,
-
, X,
÷
(PPPPPPPPP)
=
KEY
PPPPPPPPP =
amounts input for the calculation, max. 9 digits comprised
eventual decimal digits.
Note : eventual overflow situations will be indicated from the error E140.
Summary of Contents for J3500E